TO CLEAN
THE GENERATOR:
I A
CAUTION:
Never Insertany objector tool
through the air cooling slots,even if the engine is
not running,
Use a damp cloth to wipe exterior surfaces clean.
A soft, bristle brush may be used to loosen caked
on dirt, oil, etc.
A vacuum cleaner may be used to pick up loose
dirt and debris.
Low pressure air (not to exceed 25 psi) may be
used to blow away dirt. Inspect cooling air slots
and openings on the generator. These openings
must be kept clean and unobstructed.
ENGINE
MAINTENANCE
A
ANGER: When working onthegenerator
always disconnect sparkplugwirefrom sparkplug
andkeepitawayfrom sparkplug.
CHECKING OIL LEVEL
Oil level should be checked prior to each use or at
least every 8 hours of operation. Keep oil level
maintained.
CHANGING ENGINE OIL AND OIL FILTER
Change oil after first 8 hours of operation. Change oil
and oil filter every 50 hours thereafter. If you are using
your generator under extremely dirty or dusty
conditions, or in extremely hot weather, change oil
more often.
Change oil while engine is still warm from running, as
follows:
Clean area around oil drain plug.
Remove oil drain plug and oil fill plug and drain oil
completely into a suitable container.
When oil has completely drained, Install oil drain
plug and tighten securely.
Place a suitable container beneath the oil filter and
turn filter counterclockwise
to remove. Discard
according to local regulations.
Coat gasket of new filter (p/n 70185) with engine
oil. turn filter clockwise until gasket contacts tightly
with filter adapter. Then tighten an additional 3/4
turn.
Fill oil sump with recommended
oil. (See "Before
Starting the Engine" on page 8 for oil
recommendations)
Install the oil fill plug and tighten securely.
Wipe up any spilled oil.
CLEAN/REPLACE SPARK PLUG
Change the spark plug every 100 hours of operation
or once each year, whichever comes first. This will
help your engine to start easier and run better.
Replace with Champion RC12YC or equivalent.
Clean area around spark plug.
Remove and inspect spark plug.
Replace spark plug if electrodes are pitted, burned
or porcelain is cracked. For Replacement use
Champion RC12YC or equivalent.
Check electrode gap with wire feeler gauge and set
spark plug gap to 0.030 inch (0.76mm) if
necessary.
RETORQUE HEAD BOLTS
After the first 50 hours of operation, you must retorque
the head bolts 6.9 kg.-m. (44 ft.-Ibs.)
Important:
If you feel uncomfortable about doing this
procedure or you don't have the proper tools, please
take your generator in to the nearest service center to
have the head bolts re-torqued. This is a very
important step to insure the longest life for your
engine.
NOTE: Only perform this adjustment after the first 50
hours of operation. The head bolts will need no further
adjustment.
Torque sequence is as follows: A, B, C, D,
(alternating pattern).
A
g
SERVICE AIR CLEANER
Your engine will not run properly and may be
damaged if you run it using a dirty air cleaner. Clean
or replace the air cleaner paper filter once every 50
hours of operation or once a year, whichever comes
first. Clean or replace more often if operating under
dusty conditions. Clean foam pre-cleaner every 25
hours of operation or sooner under dusty conditions.
PAPER
FILTER
FOAM
PRE-FILTER