Force Adjustments - Craftsman 139.53976SRT Owner's Manual

Garage door opener 1/2 hp
Hide thumbs Also See for 139.53976SRT:
Table of Contents

Advertisement

Adjustment
Step 2
Adjust
the Force
Force adjustment controls are located on the back
)anel of the opener. Force adjustment settings
regulate the amount of power required to open and
close the door.
The door will stop in the up direction if anything
interferes with its travel. The door will reverse in the
Jown direction if anything interferes with its travel
(including binding or unbalanced doors).
If the forces are set too light, door travel may be
interrupted by nuisance reversals in the down
direction and stops in the up direction.
Weather conditions can affect the door
movement, so occasional
adjustment may be
needed.
The maximum force adjustment range is 260 degrees,
about 3/4 of a complete turn. Do not force controls
beyond that point. Turn force adjustment controls
with a screwdriver.
Adjustment Label
Too much force on the door will Interfere with
the proper
operation
of the safety
reverse
system.
The door might not reverse properly
when required and could seriously Injure or kill
someone
under it. Do not Increase the force
beyond the minimum amount required to close
the door. Do not use the force adjustments to
compensate
for a binding
or sticking garage
door. Test the safety reverse system following
all adjustments to force levels. See page 30.
Backpanetof
dooropener
Force
Adjustment
Control
How and When to Adjust the Forces
Test the DOWN (close) force
Grasp the door bottom when the door is about
halfway through DOWN (close) travel. The door
should reverse. Reversal halfway through down
travel does not guarantee reversal
on a two-inch
obstruction.
Seepage
30. If the door is hard to
hold or doesn't reverse, decrease the DOWN (close)
force by turning the control counterclockwise.
Make 10 degree turn adjustments until the door
reverses normally. After each adjustment, run the
opener through a complete cycle.
Test the UP (open) force
Grasp the door bottom when the door is about
halfway through UP (open) travel. The door should
stop. If the door is hard to hold or doesn't stop,
decrease UP (open) force by turning the control
counterclockwise.
Make 10 degree turn adjustments
until the door stops
easily. After each adjustment,
run the opener through
a complete travel cycle.
If the door doesn't open atleast5
feet
Increase UP (Open) force by turning the control
clockwise. Make 10 degree turn adjustments until
door opens completely, Re-adjust the UP limit if
necessary. After each adjustment,
run the opener
through a complete travel cycle.
If the door reverses
during the down (close) cycle
and the opener lights aren't flashing
Increase DOWN (close) force by turning the control
clockwise. Make 10 degree turn adjustments until the
door completes a close cycle. After each adjustment,
run the opener through a complete travel cycle. Do
not increase the force beyond the minimum
amount required to close the door.