Operating Procedures - Craftsman 919.162121 Owner's Manual

Permanently lubricated tank mounted air compressor
Table of Contents

Advertisement

Available languages

Available languages

OPERATING PROCEDURES
Before attaching air hose or accessories, make sure
the OFF/AUTO lever is set to "OFF" and the air
regulator is closed.
2.
Attach hose and accessories.
6.
Always operate the air compressor in well-ventilated
areas; free of gasoline or other solvent vapors.
Do not operate the compressor near the spray area.
TOO MUCH AIR PRESSURE
CREATES
A
HAZARDOUS
RISK OF BURSTING.
CARE-
FULLY FOLLOW STEPS 3 AND 5 EACH TIME
THE COMPRESSOR
IS USED.
Compressed
air from the outfit may contain
water condensation. Do not spray unfiltered air
at an item that could be damaged.
Some air
operated tools or devices may require filtered
air. Read the instructions for the air tool or
device.
3.
Check the manufacturer's
maximum pressure rating
for air
tools and accessories.
The regulator
outlet pressure must
never exceed the maxi-
mum pressure rating. If your
compressor
is not supplied
with a regulator with
gauge,
install one before using accessories.
4.
Turn the OFF/AUTO lever to "AUTO" and allow tank
pressureto build. Motor will stop when tank pressure
reaches "cut-out" pressure.
5.
Opentheregulatorbyturningitclockwise.
Adjustthe
regulator to the correct pressure setting. Your com-
pressor
is ready for use.
When you are finished:
7.
Set the "OFF/AUTO" lever to "OFF".
8.
Turn the regulator counterclockwise
and set the
outlet pressure to zero.
9.
Remove the air tool or accessory.
10.
Open the regulator and allow the air to slowly bleed
from the tank. Close the regulator when tank pres-
sure is approximately
20 psi.
11.
Drain water from air tank.
WATER WILL CONDENSE
IN THE AIR TANK. IF
NOT DRAINED, WATER WILL CORRODE AND
WEAKEN THE AIR TANK CAUSING A RISK OF
AIR TANK RUPTURE.
With tank pressu re at approximately 20 psi, open the drain
cock or drain valve.
NOTE:
If drain cock valve is plugged, release all air
pressure. The valve can then be removed,
cleaned,then
reinstalled.
12.
After the water has been drained, close drain cock
or
drain valve. The air compressor
can now be
stored.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents