Electrical Data; Use Of Extension Cords - Friedrich US12 Installation & Operation Manual

115/230 volts thru-the-wall series
Table of Contents

Advertisement

Electrical Data
Electrical Data
115V~
QT
qo
230V ~
Power cord may include a current interrupter
device. A test and reset button is provided on the
plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the RESET button. If the TEST button
does not trip or if the RESET button wilI not stay
engaged, discontinue
use of the air conditioner and
contact a qualified service technician.
USE OF EXTENSION CORDS
Becauseof potentialsafety hazards,do not usean extensioncord.
Use Wall Receptacle
Power Supply
Standard 125V,
3-wire grounding
receptacle rated
15A, 125V AC
Standard 250V,
3-wire grounding
receptacle rated
15A, 250V AC
Standa_ 250V,
3-wire grounding
receptacle rated
2gA, 250V AC
Use 15 AMP. time
delay fuse or 15 AMP
circuit breaker
Use 20 AMP. time
delay fuse or 20 AMP
circuit breaker
Electrical
Shock
Hazard
Plug into a grounded
3 prong outlet.
Do not remove
ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions
can result in
death, fire, or electrical
shock.
All wiring should be done in accordance with local electrical codes and regulations.
NOTE : Aluminum house wiring may pose special problems. Consult a qualified electrician.
•/ ELECTRICAL
SAFETY
IMPORTANT GROUNDING INSTRUCTIONS
The air conditioner has a three-prong grounding
plug on its power supply cord, which must be
plugged into properly grounded three-prong wall
receptacle for your protection against possible
shock.
FUSE - Use a time-delay fuse or circuit breaker.
Refer to the nameplate for proper power supply
requirements.
208/230 VOLT UNITS
These units are equipped with a three-prong
grounding plug on the power supply cord, which
must be plugged in to a matching, properly
grounded three-prongwall receptaclefor your
protection against possible shock hazard. If such
an outlet is not present, one must be installed by a
qualified electrician in accordancewith the National
Electrical Code and local codes and ordinances.