Inspecting Burners - Desa Comfort Glow CGB3930NRA Owner's Operation And Installation Manual

Premium aged split oak and yellow flame unvented (vent-free) natural gas log heaters
Hide thumbs Also See for Comfort Glow CGB3930NRA:
Table of Contents

Advertisement

OWNER'S
MANUAL
OPERATING
HEATER
Continued
IMPORTANT: This remote control
has been specially engineered to take
an air temperature sample every 5.5
minutes in the auto mode. It will not
respond immediately to the tempera-
ture setting being turned up or down.
IMPORTANT'The
hand-held remote
control unit must be near the heater.
Do not keep the hand-held remote
control unit too close to the heater.
The thermostat on the hand-held re-
mote control unit will heat up too
quickly and turn the heater off.
3.
Use the STATUS button on the hand-
held remote control unit to see the
operation mode being used and the
temperature setting selected. A red
light will come on beside the opera-
tion mode being used when the sta-
tus button is pressed.
4.
To turn the burners off when operat-
ing in the manual mode, press the OFF
button. If operating in the auto mode,
press the MAN button, then press the
OFF button. The pilot will remain nL
IMPORTANT." To turn the pilot off,
manually turn the control knob on the
heater to the OFF position.
©
Flame Adjustment Knob
RE_T
A
SelectorSwitchin Remote Position
Control Knob in On Position
Figure 32 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for
Remote Operation
Shows Temperature Setting
.,
I 1
Increases Room
I I _!
_(_l IV_
Temperature
(_"_
Decreases Room
_HlUi°_n_rntOo°!
!!
!h_t i
Temperature
-
t
-
Turns Bumers
The Log Heater Wi I uto
""
,l_ll
t_l
_"
I
On and Off
cally Cycle Between Pilot and
I I v
_
_
Shows Current
the Heat Setting That Has Been
_
Operation Mode
Selected.
[
Figure 33 * Thermostat
Hand-Held Remote Control Unit Selections
INSPECTING
BURNERS
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME
PATTERN
Figure 34 shows a correct pilot flame pattern.
Figure 35 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. This will cause the
therrnocouple to cool. When the thermo-
couple cools, the heater will shut down.
If pilot flame pattern is incorrect,
as shown
in Figure 35
turn heater
off (see To Turn Off Gas to
Appliance,
page 16)
seeTroubleshooting,
pagesl9through21
Pilot Burner
Thermooouple
Figure 34 - Correct Pilot Flame Pattern
PilotBurner
Thermecouple
/
Figure 35 - Incorrect Pilot Flame Pattern
MAIN BURNER
Periodically inspect all burner flame holes
with the heater running, All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no
flame present. If so, turn off heater and let
cool. Either remove blockage or replace
burner. Blocked burner flame holes will
c_atesoot.