Download Print this page

Craftsman 919.167801 Owner's Manual page 16

Oil lubricated two stage stationary
Hide thumbs Also See for 919.167801:

Advertisement

Available languages

Available languages

5.
Run the compressor for 20
minutes. Make sure the globe
valve is open and there is
minimal air pressure build-up in
tank.
6.
Check all air line fittings and
connections/piping
for air leaks
by applying a soap solution.
Correct if necessary. NOTE:
Minor leaks can cause the air
compressor to overwork,
resulting in premature breakdown
or inadequate
performance.
7.
Check for excessive vibration.
Readjust or shim air compressor
feet, if necessary.
8.
After 20 minutes, close the globe
valve. The air receiver will fill to
"cut-out"
pressure and the motor
will stop.
Before
Each Start-Up:
1.
Place On/Auto/Off
lever to
"OFF".
2.
Close the globe valve.
3.
Attach hose and accessories.
NOTE: A regulator MUST be
installed when using accessories
rated at less than 175 PSI.
Too much air
pressure causes a
hazardous risk of bursting. Check
the manufacturer's
maximum
pressure rating for air tools and
accessories.
The regulator outlet
pressure must never exceed the
maximum pressure rating.
How to Start
1.
Turn the On/Auto/Off
lever to
"AUTO" and allow tank pressure
to build.
Motor will stop when
tank pressure reaches "cut-out"
pressure.
2.
When the tank pressure reaches
"cut-out"
pressure open the
globe valve.
IMPORTANT:
When using regulator
and other accessories refer to the
manufacturer-s
instructions.
NOTE: Always operate the air
compressor
in well-ventilated
areas
free of gasoline or other combustible
vapors. If the compressor
is being
used to operate a sprayer, DO NOT
place compressor
near the spray
area.
D26625
16-ENG

Advertisement

loading