HP Surestore Disk Array 12h - And FC60 User Manual page 227

Disk array fc60 user's guide (a5277a)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Problem
HW Event
Description
Category
Power Supply
Critical
LED is amber
Temperature is
Critical
over limit
Major
Warning
Temperature is
Critical
under limit
Major
Warning
Voltage is over
Critical
limit
Major
Warning
Voltage is under
Critical
limit
Major
Warning
LED State
Status
Amber
Critical
none
Critical
Temp is
>54.5º C
none
Non-critical
Temp is
>36º C
none
Critical
Temp is
<9.5º C
none
Non-critical
Temp is
<15.5º C
none
Critical
none
Non-critical
none
Critical
none
Non-critical
Probable Cause/Solution
– An incompatible or defective
component caused a temporary
fault.
– Power supply hardware is faulty.
Unplug the power cord and wait for
the LED to turn off. Reinsert the
power cord. If fault persists, replace
the power supply.
– A fan is faulty. Check status and
correct.
– Airflow is obstructed; vents are
blocked.
– One or more slots are empty.
– Power supply is faulty. Check
status and correct.
– Room temperature is too high. If
ambient temperature cannot be
reduced in a reasonable time,
turn OFF product to prevent
shortened life.
– Temperature sensor is faulty.
Compare temperature reported
by peer BCC.
– Room temperature is too low.
– Temperature sensor is faulty.
Compare temperature reported
by peer BCC.
Power supply is faulty. Check status
and correct.
Either power supply is faulty. Check
status and correct.