Download Print this page

Maintenance - Craftsman 919.167270 Owner's Manual

Permanently lubricated tank mounted air compressor
Hide thumbs Also See for 919.167270:

Advertisement

Available languages

Available languages

ALL MAINTENANCE
AND REPAIR
OPERATIONS
NOT LISTED MUST
BE PERFORMED
BY TRAINED
SERVICE TECHNiCiAN.
_Risk
of Unsafe
Operation. Unit
cycles automatically
when power
is on. When servicing, you may
be exposed to voltage sources,
compressed
air, or moving parts.
Before servicing unit unplug or
disconnect
electrical
supply to
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool.
To Replace
or Clean
Check
Valve
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Set the On/Auto/Off
lever to
"OFF" and unplug unit.
3.
Loosen the nut on the outlet tube
and move the outlet tube to the
side.
4,
5,
Unscrew the check valve (turn
counterclockwise)
using a socket
wrench.
Make sure the valve disc moves
freely inside the check valve
and the spring holds the disc in
the upper, closed position. The
check valve may be cleaned
with a solvent, such as paint and
varnish remover.
position
nothing
is
visible,
In closed
position
disc is visible.
6.
Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
7.
Replace the outlet tube and
tighten the nut.
8.
Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
17-ENG
1000001267

Advertisement

loading