GT-1000 Technical Data
This appendix provides technical information that is relevant to
software control of the EPSON GT-1000 color image scanner. For
further details about this particular scanner model, see the
GT-1000 user's guide.
Physical Characteristics
Function level:
Maximum reading area:
Effective pixels:
Standard interface:
Optional interface:
Serial interface protocols:
Transfer rate:
Stop bit:
Parity check:
Error Indications
Scanner errors are displayed on the control panel by a
combination of the ERROR and READY lights as shown below.
Error name
Command Error
Interface Error
Fatal Error
B-2
Scanner Model Technical Data
B2
74mm
592
RS-232C serial
Bi-directional parallel
(not available)
2400, 4800, 9600, and 19200 bps
2 bits and 1 bit
None
ERROR light
On
Flashes
Flashes
105mm
840 dots at 200 dpi, 100%
READY light
On
Off
Flashes