The Identity Data-Block; The Condition Data-Block - Epson ES-1000C Reference Manual

Esc/i scanner
Hide thumbs Also See for ES-1000C:
Table of Contents

Advertisement

The Identity Data-Block

The GT-1000 sends the following data-block when it receives the
ESC I (Request identity) command.
Identity Data-Block
Order of
bytes
(Information block)
1
2
3
4
(Data)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
*(xx denotes a variable)
B-6
Scanner Model Technical Data
Data
Contents
(in hex)
02
STX code
xx*
Status
10
16 bytes
00
42
''B''
32
''2''
52
''R''
32
50
00
52
''R''
64
100
00
52
''R''
C8
200
00
41
''A''
50
592
02
48
840
03
Explanation
Header: indicates the beginning of
the data-block
Status byte: indicates the status of
the scanner and data
Byte counter: indicates the number
of bytes of data
Scanner indication
(B2 level)
Available resolution
(50 dpi)
Available resolution
(100 dpi)
Available resolution
(200 dpi)
Maximum reading area at the
maximum resolution and 100%
zoom
(main scan 592 dots by sub scan
840 dots)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents