3
Using Advanced Performance Monitoring
Clearing Filter-Based Monitor Counters
To clear a filter-based monitor counter, delete the monitor using the perfDelFilterMonitor
command, and then add the monitor again, using the appropriate command:
•
•
•
•
•
•
Saving and Restoring Monitor Configuration
You can use the perfCfgSave command to save the current end-to-end and filter monitor
configuration settings into flash memory. This enables the performance monitoring configuration to
be saved over power cycles. You can use the perfCfgRestore command to restore the saved
monitor configuration from flash memory, for example, after you power cycle the switch.
Example.
sw1:admin> perfCfgSave
This will overwrite previously saved Performance Monitoring
settings in FLASH ROM.
Please wait ...
Committing configuration...done.
Performance monitoring configuration saved in FLASH ROM.
sw1:admin> perfCfgRestore
This will overwrite current Performance Monitoring
settings in RAM.
Please wait ...
Performance monitoring configuration restored from FLASH ROM.
Use the perfCfgClear command to clear the previously saved performance monitoring
configuration settings from flash memory.
Example.
sw1:admin> perfCfgClear
This will clear Performance Monitoring settings in FLASH ROM.
The RAM settings won't change.
Please wait ...
Committing configuration...done.
Performance Monitoring configuration cleared from FLASH.
3-12
perfAddReadMonitor
perfAddWriteMonitor
perfAddRWMonitor
perfAddSCSIMonitor
perfAddIPMonitor
perfAddUserMonitor
Do you want to continue? [y|n]y
Do you want to continue? [y|n]y
Do you want to continue? [y|n]y
Advanced Performance Monitoring User's Guide
Need help?
Do you have a question about the StorageWorks 8B - FC Entry Switch and is the answer not in the manual?
Questions and answers