INSTALLATION
13) Carefully remove the bottom brick panel.
Bottom Brick Panel
14) Loosen the 2 screws that hold the right
side heat shield.
Heat
Shield
15) Lift up and pull out the heat shield slightly
to clear the head screws and then hang it
on the top bracket (located directly above
the heat shield).
Bracket
Heat
Shield
16) Disconnect the inlet gas line from the
valve.
32
17) Disconnect the 2 connectors from the
modulating coil.
18) Remove the DC Sparker wires; 1 wire for
the ignitor and 2 wires to the module box.
19) Remove the 16 screws that hold the valve
tray to the fi rebox and slightly pull out the
valve tray.
Valve Tray
Valve Tray Slightly Removed
20) Disconnect the black and red wires from
the solenoid valve.
21) Disconnect the 2 red wires and 1 black
wire from the valve.
Modulating Coil
Wires
22) Completely pull out the valve tray.
23) Replace the front burner orifi ce with orifi ce
#56. See image below. Use another wrench
to hold onto the elbow behind the orifi ce.
24) Replace the back burner orifi ce with orifi ce
#53. See image below. Use another wrench
to hold onto the elbow behind the orifi ce.
Front Burner
Rear Burner
Orifi ce
Orifi ce