Optional Remote Control; Optional Wall Thermostat; Final Check - FPI L234-NG Owners & Installation Manual

Gas insert
Hide thumbs Also See for L234-NG:
Table of Contents

Advertisement

INSTALLATION
OPTIONAL REMOTE
CONTROL
IMPORTANT
Due to the extreme heat this gas insert
emits, brick panels are required to be
installed in the unit when using either
remote control option.
Use of FPI Remote Control Kit #910-399 or
#910-368 is approved for this unit. Use of other
systems may void your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
Refer to Remote Control manual for complete
user setup and operation instructions.
Remote Receiver Installation
1) Remove the control switch from the remote
receiver by gently pulling out.
Control
Switch
Remote
Receiver
2) Remove the spring loaded battery pack by
pushing in and then pulling out.
Battery
Pack
3) Remove the receiver from the bracket and
discard the bracket.
Bracket
30
4) Re-install the control switch and the battery
pack (with batteries).
5) Remove the peel off from the velcro on the
receiver bracket on the left side of the unit.
6) Secure the receiver to the velcro on the
recevier bracket.
Receiver
7) Run the receiver wires under the base of the
fi rebox to the left side of the unit.
8) Connect the reciever wires to the valve.
9) Secure the loose wires under the fi rebox
in the wire clips located on the base of the
fi rebox.
Receiver
Receiver Bracket
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired,
follow the wiring diagram below. Note: the wires
are connected to the "TH" on the gas valve. Use
the table below to determine the maximum wire
length. FPI offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC
or UL approved may be used.
It is recommended that the thermostat be
installed on an interior wall.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:
1) Clocking the appliance to ensure the
correct fi ring rate (rate noted on label) at
15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of
the manufacturer.
®
Regency
L234 Direct Vent Gas Insert