Connect Range To Gas - GE P2B918 Owner's Manual & Installation Instructions

Self-cleaning dual fuel convection
Table of Contents

Advertisement

Read these instructions
completely
and carefully.
[]
Gas Suppl9 Requirements
Recommended
Gas Pipe Outlet Locations
NOTE: Make gas connections
on
the left side of the cutout opening.
Recommended area
for through-the-wall
connection of pipe
stub/shut-off va re.
This area allows flush
installation to rear
wall.
Recommended area for
through-the-floor
connection
of pipe stub/shut-off va re.
Provide
Adequate
Gas Supply
Your range is designed
to operate
at a pressure
of 5" of water column
on natural
gas or,
if designed
for LP gas (propane
or butane),
10" of water
column.
Hake sure you are supplying your range with
the type of gas for which it is designed,
This range is convertible for use on natural or
propane gas. If you decide to use this range on
LP gas, conversion must be made by a qualified
LP installer before attempting to operate the
range on that gas.
For proper operation, the pressure of natural
gas supplied to the regulator must be between
5" and 13" of water column.
For LP gas, the pressure supplied must be between
10" and 13" of water column.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1"
greater than the operating (manifold)pressure
as given above.
The pressure regulator located at the inlet of
the range manifold must remain in the supply line
regardless of whether natural or LPgas is being
used.
A flexible metal appliance connector used to
connect the range to the gas supply line should
have an I.D.of 1/2" and be 5 feet in length for ease
of installation.