Dell PowerEdge EL Owner's Manual page 161

Dell poweredge r720 and r720xd owner's manual
Hide thumbs Also See for PowerEdge EL:
Table of Contents

Advertisement

Error Code
Message Information
SEC0031
Message
LCD Message
Details
Action
SEC0033
Message
LCD Message
Details
Action
SEL0006
Message
Details
Action
SEL0008
Message
Details
Action
SEL0012
Message
Details
Action
SEL1204
Message
LCD Message
Details
The chassis is open while the power is on.
Intrusion detected. Check chassis cover.
The chassis is open. System performance may be degraded, and
security may be compromised.
Close the chassis. Check system logs.
The chassis is open while the power is off.
Intrusion detected. Check chassis cover.
The chassis was opened while the power was off. System security
may have been compromised.
Close the chassis and verify hardware inventory. Check system logs.
All event logging is disabled.
This message is displayed when all event logging has been disabled
by the user.
If unintended, re-enable logging.
Log is full.
When the event log is full, additional events are not written to the log.
Older events may be overwritten and lost. This message may also
appear if the user disabled event logging.
Backup and clear log.
Could not create or initialize the system event log.
If the system event log fails to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
Reboot the management controller or iDRAC. Cycle system input
power. If problem persists call support.
An unknown system hardware failure detected.
Unknown system hardware failure.
If the system event log failed to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
161