76
6
Tighten the lamp attachment screws firmly.
7
Install the lamp cover.
• Install the lamp and the lamp cover securely. If the lamp or the lamp cover is not
installed correctly, this unit will be turned off as a safety precaution.
• This product includes a lamp component that contains mercury (Hg). Please
consult your local regulations regarding disposal or recycling.
Do not dispose of it with normal waste.

Resetting the lamp operating time

After the lamp has been replaced, make sure you initialize the Lamp Hours
setting.
The unit has a built-in counter that keeps track of the lamp operating time and
the lamp replacement message is displayed based on this counter.
1
Connect the power cable, and press
2
Press
and when the menu appears, set the "Info" to
"Reset Lamp Hours".
.