12. Replace the outlet tube and
tighten nuts.
13. Replace shrouds and console.
14. Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
To Replace
Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug air comrpessor.
3.
Remove the regulator ring and
remove the console cover.
gauge and quick connect.
Regulator
Ring
4.
5.
Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
Using an adjustable wrench,
rotate the pressure switch
assembly as shown.
6.
Remove the outlet pressure
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
7.
Remove the regulator.
8.
Apply pipe sealant tape to the
nipple.
9.
Assemble the regulator and
orient as shown.
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
10.
11.
Reapply pipe sealant to outlet
pressure gauge, tank pressure
gauge, and quick connect.
Reassemble outlet pressure
gauge, tank pressure gauge, and
quick connect. Orient outlet
pressure gauge and tank
pressure gauge to read correctly.
Tighten quick connect with
wrench.
12. Rotate pressure switch assemble
into correct position.
13. Replace console cover and
regulator ring.