Operation; Priming The Pump - Craftsman 390.2532 Owner's Manual

Multi-stage jet pump
Table of Contents

Advertisement

OPERATION
Priming
The
Pump
I&WARNING ]Burn
hazard.
NEVER
run
pump
dry.
Running
pump
without
water
may
cause
pump
to overheat,
damaging
seal
and possibly
causing
burns
to persons
handling
pump.
Fill pump
with
water
before
starting.
IAWARNING]Risk
of explosion
and
steam
burns.
NEVER run pump
with discharge
shut
off, which
can boil water
inside
pump
body.
Steam
in pump
may
cause
it to explode
and
scald
anyone
near.
NOTICE:
Open
water
system
faucets
before
priming
pump
for the first time.
1.
Remove
pressure
gauge.
a. Close regulator
valve (turn clockwise
- see Figure
]8A).
b. Fill pump
and suction
pipe with water
(Figure
lSB).
c. Replace
pressure
gauge,
using
Teflon
tape on
thread;
tighten
gauge.
NOTICE:
If a priming
tee and plug have been installed
for a long horizontal
rim, be sure to fill suction
pipe
through
this tee and replace
plug.
(Don't
forget
to
teflon tape the plug.)
2.
Start Pinup:
Pressure
should increase
rapidly to 50 pounds
per
square
inch or more as ejector
and pump
prime.
If
so, go to step 4, below.
lf pressure
does not build to 50PSI,
repeat steps a,
b, and c under
Step No.1 two or three times to re-
move entrapped
air from the suction
pipes.
3.
If pressure
does not build up after priming
pump
several times, check the following:
a. Suction
pipe in the water.
b. Suction
pipe has no leaks.
NOTICE:
Air can leak in even where
water won't
leak
out. Make sure all joints are tight.
c. Control
valve, check valve, or foot valve installed
and operating
correctly.
d. Pump trying to lift water more than rated lift for
deep well ejector
used (including
compensation
for horizontal
offset).
e. Be sure pump
is not airlocked.
In offset install-
ations,
pump
suction
port
should
be highest
point in suction
pipe; there should be no sags in
suction
pipe (run it straight
and at a slight angle
upward
from well head to pump).
A - Close Regulator
I
2360a 0697
B - Fill Pump With
Water
l_
C - Start
Pump i
Figure
18 - Priming
Pump
1030a 0697
D - Adjust
Regulator
10

Hide quick links:

Advertisement

Table of Contents
loading