3.3. Setting of jumpers

Your application may require the removal or installation of jumpers of the SMCT
Board. Before continuing, consult Table 6 which outlines the function and factory-set
condition of each jumper.
In order to access the SMCT Board it is necessary to remove the SMDP Board. This is
accomplished by:
1. Disconnecting the Mechanism Cable and the AC cable.
2. Removing the six (6) screws on the SMDP Board and the two (2) screws located
in the heat sink on the right side of the board.
3. Lifting the Board from the rear center, in the connector area, to avoid damage.
NOTE:
Any changes in this area should be performed by an experienced technician.
J u m p e r
Not used
J1
ON
J2
OFF
J 3
Both ON = Polar
J 4
Both OFF = Neutral
J5
J6
Not used
Not used
J 7
Current Loop (USA Version)
J8
J 9
Both are ON when not
J10
using RTS and CTS
J11
ON when using CTS
ON when using RTS
J12
80 mA Current Loop
J13
60 mA Current Loop
J14
40 mA Current Loop
J15
J16
20 mA Current Loop
Note 1: Select either J2 or J3. Do not connect both.
Note 2: Select
1 only. Do not connect 2 or more.
Table 6
Function and Conditions of Jumpers
RS-232C
Level
Function
OFF
Current Loop
Level
O N
- 1 2 -
Factory-set
OFF
ON
Note 1
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
Note 2
OFF
OFF