Figure 26 I/O tab of Disk Enclosure Properties window
NOTE:
enclosures.
If the fields Assembly serial number, Hardware revision, and Hardware type on the I/O
tab of the Disk Enclosure Properties window are blank, you can optionally reset the I/O
modules to clear the blank fields after the I/O module firmware upgrade has completed
successfully. Note that blank fields do not affect the array's ability to process host I/O.
See
e.
Check the operational states that you recorded and proceed as follows:
18. Check the event log for the code-load-blocked code (066df308, critical event). If you do not
see this event, contact your HP-authorized service representative for assistance. If you see this
event, continue with
54
Upgrading the Enterprise Virtual Array
The Firmware revision fields are different for EVAx400 and P6000 disk
"Resetting the I/O module" (page 55)
Good: No action
Loading firmware: The I/O module firmware load is blocked. Corrective action is
required somewhere on the array (but not on this I/O module). Continue with
18
Any state other than Good or Loading firmware: Corrective action is required on
this I/O module. Continue with
Step
19.
for more information.
Step
18.
Step

Hide quick links: