GE Zoneline 3200 Owner's Manual page 15

Zoneline series
Hide thumbs Also See for Zoneline 3200:
Table of Contents

Advertisement

1
Install the Wall Case and the Exterior Grille
1 The RAB71 or RAB77 wall case must be
properly installed per instructions packed
with the case.
2 Remove the corrugated stiffener and the
outdoor protective panel. Use the slit in the
outdoor panel as a handhold and push out.
Protective
panel
Stiffener
3 Install the exterior grille from the room side
following instructions packed with the grille.
2
Remove the Shipping Tape from the Room Cabinet
1 Carefully remove shipping tape, if there is any,
from the room cabinet and vent door.
Shipping tape
Slit
Insulated Wall Case
This chassis is designed to be installed in a
GE plastic or an insulated steel wall case. This
minimizes condensation from forming on the
room side of the case.
The RAB71 wall case is insulated. Insulation kit
RAK901L is available for use with RAB77 or
existing uninsulated wall cases when needed.
NOTE: For installation with a subbase or duct
adapter, see the instructions packed with those kits.
2 Remove the room cabinet by pulling it out at
the bottom to release it, then lift it up to clear
the rail along the unit top.
2
1
15