Carrier RAV-SP180UT-UL Installation Manual page 30

Air conditioner (split type); 4-way air discharge cassette type
Hide thumbs Also See for RAV-SP180UT-UL:
Table of Contents

Advertisement

4-way Air Discharge Cassette Type
3
Procedure
1. Using temp. setup
No. [12].
(CODE No. [12]: Line address)
2. Using timer time
address from [3] to [2].
3. Push
button.
In this time, the setup finishes when the display
changes from flashing to lighting.
Indoor UNIT No. before setup change is displayed.
4
Procedure
1. Using temp. setup
No. [13].
(CODE No. [13]: Indoor address)
2. Using timer time
address from [3] to [2].
3. Push
button.
In this time, the setup finishes when the display
changes from flashing to lighting.
Indoor UNIT No. before setup change is displayed.
29-EN
/
buttons, specify CODE
/
buttons, change the line
/
buttons, specify CODE
/
buttons, change the indoor
5
Procedure
1. Using temp. setup
No. [14].
(CODE No. [14]: Group address)
2. Using timer time
data from [0001] to [0002].
(Setup data [Header unit: 0001] [Follower unit:
0002])
3. Push
button.
In this time, the setup finishes when the display
changes from flashing to lighting.
Indoor UNIT No. before setup change is displayed.
6
Procedure
If there is other indoor unit to be changed, repeat
2
5
procedure
to
to change the setup.
When the above setup has finished, push
select the indoor UNIT No. before change of setup,
specify CODE No. [12], [13], [14] in order with temp.
setup
/
buttons, and then check the changed
contents.
Address change check Before change:
[3-3-1] → After change: [2-2-2]
Pushing
button clears the contents of which setup
was changed.
(In this case, procedure from
Indoor UNIT No. before setup change is displayed.
– 29 –
Installation Manual
/
buttons, specify CODE
/
buttons, change the setup
2
is repeated.)
to

Advertisement

Table of Contents
loading

Table of Contents