Computer-Based Instruments NI 5401 User Manual PXI /PCI Arbitrary Function Generator ™ NI 5401 User Manual March 1999 Edition Part Number 322419A-01...
90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period.
Page 4
Conventions The following conventions are used in this manual: » The » symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box.
Software Options for Your NI 5401 ................1-8 Software Included with Your NI 5401 ............1-8 VirtualBench ..................1-8 NI-FGEN Instrument Driver .............1-9 Additional National Instruments Development Tools........1-9 LabVIEW ..................1-9 LabWindows/CVI ................1-10 ComponentWorks ................1-10 Using the Soft Front Panels to Generate Waveforms ............1-11 Generating Standard Functions ...............1-11...
Page 6
VirtualBench-FG Signals Settings Dialog Box for the NI 5401... 1-12 Figure 1-9. VirtualBench-FG Load Waveform Dialog Box........1-13 Figure 1-10. VirtualBench-FG Frequency List Editor Dialog Box ......1-14 Figure 1-11. Waveform Editor Soft Front Panel ............1-15 NI 5401 User Manual www.natinst.com...
Generating Functions with the NI 5401 The NI 5401 User Manual describes the features, functions, and operation of the NI 5401 arbitrary function generator. This device performs comparably to standalone instruments while providing the flexibility of computer-based operation. About Your NI 5401 Thank you for buying a National Instruments NI 5401 arbitrary function generator.
The front panel contains three types of connectors: BNC, SMB, and 50-pin very high-density SCSI (VHDSCSI). The main waveform is generated through the connector labeled ARB. LOCK ACCESS ARB OUT EXT TRIG SYNC PLL IN PLL REF SYNC OUT Figure 1-1. NI 5401 I/O Connectors NI 5401 User Manual www.natinst.com...
RTSI bus using the 20 MHz RTSI clock signal. You can frequency lock the NI 5401 for PXI to other National Instruments devices using the 10 MHz backplane clock. If no external reference clock is available, the NI 5401 automatically tunes the internal clock to the highest accuracy possible.
The cable connects to the digital connector on the NI 5401. Figure 1-5 shows the 68-pin connector pin assignments on the SHC50-68 cable. Note The SHC50-68 connector uses the same signals as the NI 5401 digital output connector shown in Table 1-1. NI 5401 User Manual www.natinst.com...
ASCII text file and generate them repeatedly. You can generate these waveforms with a resolution of approximately 10 mHz and perform frequency sweeps and shift-keying. As with all VirtualBench instruments, you can load and save instrument settings. NI 5401 User Manual www.natinst.com...
An NI-FGEN Instrument Driver Quick Reference Guide is included in your NI 5401 kit. This reference guide helps you program your NI 5401. Additional National Instruments Development Tools The following sections describe several additional tools that you can use to develop complex applications for your NI 5401.
ComponentWorks features instrumentation-based graphical user interface (GUI) tools, including graphs, meters, gauges, knobs, dials, and switches. Note Use the NI-FGEN instrument driver to program and control your NI 5401 using ComponentWorks. NI 5401 User Manual 1-10 www.natinst.com...
Figure 1-7. VirtualBench-FG General Settings Dialog Box for the NI 5401 Figure 1-8. VirtualBench-FG Signals Settings Dialog Box for the NI 5401 Note Refer to the online help for further information about the 54xx Settings dialog box. NI 5401 User Manual 1-12 www.natinst.com...
To return to the main VirtualBench-FG screen shown in Figure 1-6, select File»Close. Select File»Load Frequency List to load the frequency list. You can combine the frequency list generation with different trigger modes to get the desired frequency generation. NI 5401 User Manual 1-14 www.natinst.com...
You can use the Waveform Editor shown in Figure 1-11 to create a custom waveform. To launch the Waveform Editor, select Start»Programs» National Instruments FGEN»Waveform Editor. You can select waveforms from the function library, write equations, or draw them manually. Each segment can have more than one waveform component in it, and you can perform a variety of math functions on each component.
Output attenuation is set to 0 dB. • The analog filter is enabled. • Output impedance is set to 50 • The PLL reference source is set to internal tuning. • The SYNC duty cycle is set to 50%. NI 5401 User Manual 1-16 www.natinst.com...
Digital Filter Enable Div/2 80 MHz Oscillator Figure 2-2. Waveform Data Path Block Diagram On the NI 5401, the high-speed DAC is always updated at 80 MHz, but the update clock for memory is 40 MHz. NI 5401 User Manual www.natinst.com...
You can also use an external trigger from a pin on the digital I/O connector, the RTSI trigger lines on the RTSI bus, or the TTL trigger lines on the PXI trigger bus on the backplane. Figure 2-4 shows the trigger sources for the NI 5401. NI 5401 User Manual www.natinst.com...
Figure 2-6 illustrates a continuous trigger mode of operation. Repeat End of All Stages Start Trigger Until Stopped (f1, T1 (f2, T2 (f1, T1 (f2, T2 (f3, T3 (f4, T4 Figure 2-6. Continuous Trigger Mode NI 5401 User Manual www.natinst.com...
You can switch off the analog lowpass filter at any time during waveform generation. When you change this setting, the bouncing of electromechanical relays on the NI 5401 distorts the output signal for about 10 ms. NI 5401 User Manual www.natinst.com...
You can change the output enable state at any time during waveform generation. When you change this setting, the bouncing of electromechanical relays on the NI 5401 distorts the output signal for about 10 ms. NI 5401 User Manual 2-10 www.natinst.com...
5 V pk-pk Note If two or more NI 5401 devices are locked to each other using the same reference clock, they are frequency locked, but the phase relationship is indeterminate. NI 5401 User Manual 2-12 www.natinst.com...
EEPROM, calculating correction values, and writing those values to the CalDACs. National Instruments calibrates all NI 5401 devices to the levels indicated in Appendix A, Specifications. Factory calibration involves procedures such as nulling the offset and gain errors. However, since offset and gain errors may drift with time and temperature, you may need to recalibrate your device.
Data interpolating frequency ..80 MS/s Pipeline signal delay .......26 sampling periods Analog Type..........7th-order L-C lowpass filter Passband ripple........±2 dB With less than 10 dB of attenuation, signal maximum plus offset (before attenuation) must not exceed ±5 V (into 50 NI 5401 User Manual www.natinst.com...
Optional Accessories National Instruments offers a variety of products to use with your NI 5401, including probes, cables, and other accessories: • Shielded and unshielded I/O connector blocks (SCB-68, TBX-68, CB-68) • RTSI bus cables For more specific information about these products, refer to your National Instruments catalogue or Web site, or call the office nearest you.
Page 45
(N–L–D+1) of 2 . In other words, for an effective update rate of every sample at half the maximum clock rate, write a frequency value of (32–14–2+1) )) / 2 , which equals 1.221 kHz. NI 5401 User Manual www.natinst.com...
Technical Support Resources This appendix describes the comprehensive resources available to you in the Technical Support section of the National Instruments Web site and provides technical support telephone numbers for you to use if you have trouble connecting to our Web site or if you do not have internet access.
Page 47
If you have trouble connecting to our Web site, please contact your local National Instruments office or the source from which you purchased your National Instruments product(s) to obtain support. For telephone support in the United States, dial 512 795 8248. For...
Page 53
PCs and work-stations; it offers a theoretical maximum transfer rate of 132 Mbytes/s. PCLK digital pattern clock output peak-to-peak a measure of signal amplitude; the difference between the highest and lowest excursions of the signal NI 5401 User Manual www.natinst.com...
Page 54
For example, a system has 12-bit resolution, one part in 4,096 resolution, and 0.0244 percent of full scale. RTSI bus Real-Time System Integration bus—the National Instruments timing bus that connects DAQ boards directly, by means of connectors on top of the boards, for precise synchronization of functions...
Page 55
TTL version of the sine waveform output signal generated by the NI 5401 trigger any event that causes or starts some form of data capture transistor-transistor logic update rate the rate at which a DAC is updated NI 5401 User Manual www.natinst.com...
Page 58
1-13 to 1-14 continuous trigger mode, 2-6 single trigger mode, 2-5 to 2-6 stepped trigger mode, 2-7 trigger sources, 2-4 to 2-5 National Instruments Web support, D-1 to D-2 waveform generation, 2-2 NI 5401. See also function generator operation. block diagram, 2-1...
Page 60
1-13 to 1-14 generating standard functions, 1-11 to 1-13 using Waveform Editor, 1-15 waveform specifications, A-3 Web support from National Instruments, D-1 to D-2 online problem-solving and diagnostic resources, D-1 software-related resources, D-2 Worldwide technical support, D-2 NI 5401 User Manual www.natinst.com...