Powering On The Server; Powering On The Server - Fujitsu SPARC Enterprise M4000 Installation Manual

Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

Note – setdualpowerfeed requires a complete chassis power cycle (all power
cords removed) to apply any changes. Make certain to allow 30 seconds before
plugging the power cords back into the chassis.
To perform XSCF initial settings, use the XSCF default user account. Until user
accounts for user environment is registered, log in with a default user account and
default password. The privileges of the default user are useradm and platadm.
2. Log in to the XSCF Shell using a user account and password set during Step 1.
See the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User's
Guide for details on how to log in to the user account.
3.4

Powering On the Server

This section explains how to power on the server the first time.
1. Set the key on the operator panel to the Service position.
2. From the XSCF Shell, type the console command:
XSCF> console -d 0
3. Confirm that the XSCF STANDBY LED (green) on the operator panel is lit.
4. Push the power switch on the operator panel to power on the server.
The server starts and begins a self-diagnosis.
Watch the initial system administration console for error messages during the boot
process. See
5. Confirm that "ok" is displayed on the domain console.
3-10
SPARC Enterprise M4000/M5000 Servers Installation Guide • December 2010
Appendix B
for fault installation information.