Download Print this page
Panamax MR4300 Reference Manual

Panamax MR4300 Reference Manual

Reference guide

Advertisement

Quick Links

Model MR4300 Reference Guide
Front Panel Features
MEDIA LIGHTS - Can be rotated 45° left or right.
MR4300
POWER ON / OFF
FOR ALL OUTLETS
BANK 1
ON / OFF INDICATORS FOR OUTLET BANKS 1 AND 2
Back Panel Features
15A RESETTABLE CIRCUIT BREAKER
GROUND
LUG
8 ft. POWER CORD
15 AMP
MAIN POWER
CIRCUIT
120 VAC/15A
BREAKER
with Right Angle
45° Low Profile Plug
15 AMP
MAIN POWER
CIRCUIT
120 VAC/15A
BREAKER
GROUND LUG
IMPORTANT SAFETY POINTS
Panamax surge protectors and the connected equipment must be indoors, in a dry location and in the same
building. Although your Panamax protector is very durable, its internal components are not isolated from the
environment. Do not install any Panamax product near heat emitting appliances such as a radiator or heat register.
Do not install this product where excessive moisture is present; for example near a bath tub, sink, pool basement
floor, fish tank, etc. It is not uncommon for a building to be improperly grounded. In order to protect your equipment,
Panamax products must be plugged into a properly wired and grounded 3-wire outlet. Additionally, building wiring
and grounding must conform to applicable NEC (USA) or CEC (Canada) codes for the Panamax protection policy to
be valid. Do not use 2-blade adapters or any other "power strips" with this product. Use only Panamax extension
cord, or a UL / CSA recognized power cord.
MR4300 Features and Specifications
Key Features
Exclusive Automatic Voltage Monitoring (AVM)
Panamax's patent pending power monitoring
circuitry constantly monitors the AC line voltage
for unsafe voltage conditions such as momentary
spikes, prolonged over-voltages and undervoltag-
es (brownouts). These unsafe conditions pose a
very dangerous threat to all electronic equipment
within the home. If the MR4300 senses an unsafe
power condition, it will automatically disconnect
power from your equipment from the to protect
equipment from damage. The front panel indica-
tor will also alert users to the power condition.
Once the voltage returns to a safe level, the
MR4300 will automatically reconnect the power
to the outlets.
Protect or Disconnect™ Technologies
In the event of a catastrophic surge such as light-
ning, it completely disconnects AC power to con-
nected equipment.
Front Panel Outlet
MR4300 features a protected and noise filtered
convenience outlet located on the front panel.
Perfect for temporary gaming systems, por-
table electronics (such as music players or smart
phones), or other personal electronics.
Note to CATV Installers:
This reminder is provided to call attention to Article 820-40 of the NEC. That article provides
specific guidelines for proper grounding.It specifies that the cable ground shall be connected
to the grounding system of the building and as close to the point of entry as practical.
Español - Para la versión en español de este documento, vaya a www.panamax.com/products
Français - Pour la version espagnole de ce document, allez à www.panamax.com/products
Panamax LLC, 1690 Corporate Circle, Petaluma, CA 94954 • 707-283-5900 • 800-472-5555 • www.panamax.com
UNSAFE VOLTAGE INDICATOR normally OFF; when lit, indicates that incoming voltage is unsfe
VOLT METER
and the surge protector has disconnected the power to protect your equipment.
BANK 2
MR4300
ON / OFF CONTROL FOR DECORATIVE BLUE LIGHTS
BANK 1
BANK 2
(Blue lights can be illuminated when power is off)
BANK 2 - HIGH CURRENT OUTLETS
GROUND
LUG
BANK 2 - HIGH CURRENT OUTLETS
ALL AC OUTLETS (FRONT AND BACK) INCLUDE
SURGE PROTECTION AND POWER FILTRATION
Front Panel Decorative Lights
Blue decorative lights add an attractive look at feel
to your equipment rack or TV cabinet.
Antenna, Cable, Sat and LAN Signal protection
Coaxial protection circuits prevent damaging
surges from entering through signal paths and
have the smallest signal loss on the market - less
than 0.5 db of attenuation from 0Hz to 2.2GHz.
Our coaxial protection has been specifically
designed to virtually eliminate signal loss. The
clamping level of 75V will meet and exceed the
demands of both cable and satellite voltages
while minimizing exposure to damaging spikes
and surges. LAN protection allows for 10/100
base-T Ethernet equipment to integrate into an
audio/video system without the risk of upstream
surge damage from a gateway, switch, router or
other network device.
Eight Protected and Filtered Power Outlets (see
specifications)
Eight Foot Power Cable with Low Profile Plug
This 45° angle low profile plug allows your
equipment to be as close as it can get to the wall
outlet while not blocking an adjacent outlets.
The 8' power cord means your installation loca-
tion isn't restricted by wall outlet location. Don't
let your electronics control your lifestyle.
©2012 Panamax LLC, Panamax Logo is a US registered trademark of Panamax
LINE FAULT INDICATOR Normally not lit.
However, if it is LIT call a licensed electrician for proper and safe wiring for your wall outlet.
LAN SURGE PROTECTION 1 PAIR OF RJ-45 IN/OUT CONNECTORS
LAN
The protection circuit will only function if connected properly.
(IN from wall outlet and OUT to equipment)
BANK 1 - LINEAR FILTRATION
BANK 1 - LINEAR FILTRATION
TEL SURGE PROTECTION 1 PAIR OF RJ-11 IN/OUT CONNECTORS
The protection circuit will only function if connected properly.
(IN from wall outlet and OUT to equipment)
TO GET STARTED
1. Turn OFF the power to all equipment that will be plugged into the MR4300.
2. Plug the MR4300 into the wall outlet then turn it ON.
3. Verify that the LINE FAULT INDICATOR LED is NOT lit, indicating that the wall outlet is properly wired and
grounded. (If it is LIT call a licensed electrician to inspect and implement proper and safe wiring).
4. Plug the equipment to be proteced into the MR4300 AC outlets and leave everything off until after the
LAN, TELEPHONE and COAX Lines are connected and then proceed to turn on your connected equipment.
AC PROTECTION
Protect or Disconnect Circuitry_________________________________________________Yes
Patented Power Management Circuit____________________________________________Yes
Overvoltage Shutoff____________________________________________________ 140V ±4
Undervoltage Shutoff___________________________________________________ 95V ±3V
Thermal Fusing___________________________________________________________Yes
Line Voltage___________________________________________________120VAC, 50/60HZ
Initial Clamping Level__________________________________________ 200V Peak, 141VRMS
Voltage Protection Rating (UL 1449 3rd Edition, 3,000A)____________________________330V
Protection Modes_________________________________________________ L-N, L-G, N-G
Maximum Current Rating_____________________________________________15A (1800W)
EMI/RFI Noise Filtration______________________________ Panamax Level 3 Noise Filtration*
Response Time__________________________________________________________< 1ns
Single Pulse Energy Dissipation_________________________________________1350 Joules
Peak Impulse Current___________________________________________________52,000 A
LAN PROTECTION
Clamping Level____________________________________________________ 62±6V @ 1 mA
Compatibility____________________________________________________10/100/1000bT
Wires Protected _______________________________________________________8-Wires
Connectors____________________________________________________________RJ-45
TEL PROTECTION
Fuseless/Auto-Resetting________________________________________________Yes
Clamping Level__________________________________________________________260V
Wires Protected _________________________________________________ 2 wire, 1 pair (4, 5)
Connectors_________________________________________________________RJ-11
UNIVERSAL COAX PROTECTION
HD 1080 i/p Ready_________________________________________________________Yes
Bidirectional__________________________________________________________Yes
Shielded____________________________________________________________Yes
Clamping Level___________________________________________________________75V
Frequency Range_________________________________________________OMHz - 2.2 GHz
Insertion Loss_________________________________________________________ <0.5 dB
Specifications subject to change due to product upgrades and improvements.
*
Go to www.panamax.com for detailed noise filtering information.
COAXIAL SURGE PROTECTION
LAN
IN
IN
IN
OUT
2 PAIRS UNIVERSAL IN/OUT
CATV / SAT 1
CATV / SAT 2
TEL
TEL
IN
OUT
OUT
OUT
UNIVERSAL COAX PROTECTION
LAN
LAN
IN
IN
IN
OUT
CATV / SAT 1
CATV / SAT 2
TEL
TEL
IN
OUT
OUT
OUT
UNIVERSAL COAX PROTECTION
MEDIA LIGHTS
CONTROL
FRONT PANEL
CONVENIENCE OUTLET
USB CHARGER
CONNECTORS
RACK MOUNTABLE.
RACK EARS NOT INCLUDED,
SOLD SEPARATELY
DIN-00015 - REV. C

Advertisement

loading

Summary of Contents for Panamax MR4300

  • Page 1 Do not use 2-blade adapters or any other “power strips” with this product. Use only Panamax extension 4. Plug the equipment to be proteced into the MR4300 AC outlets and leave everything off until after the cord, or a UL / CSA recognized power cord.
  • Page 2 Panamax products purchased through the Internet do not carry a valid Product Warranty or Connected Equipment Protection Policy unless purchased from an Authorized Panamax Internet Dealer and the original factory serial numbers are intact (they must not have been removed, defaced or replaced in any way). Purchasing from an Authorized Panamax Internet Dealer insures that the product was intended for consumer use, has passed all quality inspections and is safe.