TECHNICAL DATA

Dimensions
Electrical connection
Water supply pressure
Capacity

INSTALLATION

There should be a minimum
2mm gap between the top of
the dishwasher and
underside of bench top
820-880 mm
Warning! Make sure that the mains
plug is disconnected from the mains
socket during installation.
Install the appliance under a kitchen coun-
ter.
If a repair is necessary, the appliance must
be easily accessible for the engineer.
Put the appliance adjacent to a water tap
and drain.
For the venting of the appliance only water
hoses and mains cable openings are nec-
essary.
Width
Height
Depth
Voltage
Overall power
Fuse
Frequency
min.
max.
Place settings
The hose s hould not be
extended by more than
2 metres or water pump-
out problems ma y occu r
Secure dishwasher with
brackets and screws provided
Gap on both sides should be
equal, & no greater than
5 mm per side.
kickplate fixing screws
If floor is not level, adjust
levelling legs to suit
600 mm
Remove entire plastic
membrane from sink trap
spigot & fit drain hose to spigot
with clamp
600 mm max.
300 mm min.
The appliance has adjustable feet to allow
the adjustment of its height.
Make sure that the water inlet hose, the
drain hose and the mains cable are not
bent or squashed, when you insert the ap-
pliance.
electrolux 17
596 mm
818 - 878 mm
580 mm
220-240 V
2200 W
10 A
50 Hz
50 kPa (7 psi)
800 kPa (116 psi)