VENTILATION HEIGHTS

It is essential that all maximum or minimum dimensions are
strictly maintained, as the performance of the refrigerator is de-
pendent on adequate fl ow of air over the rear of the refrigerator.
Minimum ventilation heights
Roof vent and
lower side vent
inches
RM2351
31
RM2354
RM2451
37-3/4
RM2454
RM2551
44-1/2
RM2554
RM2652
57-3/4
RM2662
RM2663
RM2852
63-3/4
RM2862
RM3862
NDR1062

CLEARANCES

Minimum clearances (in inches) to combustible materials:
Top (G)
0
Side (K)
0
Bottom (L)
0
Rear (M
)
0 / 1
1
(RM2351 &
1
M: The distance between the rearmost part of the refrigerator and the
wall behind it.
VENTILATION REQUIREMENTS