Ventilation Heights - Dometic RM 2191 Installation & Operating Instructions Manual

Dometic refrigerators for mobile home or recreational vehicle
Hide thumbs Also See for RM 2191:
Table of Contents

Advertisement

INSTALLATION ABOVE
FLOOR HEIGHT

5. VENTILATION HEIGHTS

Refer to FIG 1 & FIG. IA., Pages 1 & 2
I n s t a l l a t i o n w i t h
Upper side vent
And lower side vent
REFRIGERATOR
I
Metal Side Vents
(1) RM 123 Upper Vent
(1) RM 183 Lower Vent
I
RM 2193
Metal 8 Plastic Side Vents
(1) RM 123 Upper Vent
(1) 3107560.009 Lower vent
These dimensions represent the minimum height
l
allowable. It is recommended the Upper Vent be
located to the maximum possible height of the
vehicle for optimum performance in warmer climates.
Minimum Ventilation
l
Height "N"
I N C H E S
MM
I
I
20 518"
524
I
2 0 518"
524
6. CLEARANCES
Minimum clearances in inches to combustible materials
are:
G:
Side
K:
B o t t o m
L:
Rear
M:
S e e N O T E
N:
P:
See N O T E
NOTE: Clearance "M" is between the rearmost
the refrigerator and the wall behind the refrigerator.
NOTE: Clearance "N" is the distance between the bot-
tom of the lower vent to the top of upper side vent. For
ventilation height, refer to Section A. Installation, Item 5.
Ventilation Heights. See FIG. 2.
Surfaces directly above and sides adjacent to the
flue outlet must be of, or covered with, fireproof
material. See FIG 2.
NOTE: Clearance "P" over top of unit condenser fins is
wed over the condenser fins. Whenever possible, increa-
se this height by up to 11 inches: the more ventilation
you provide, the better the performance you can expect
from the refrigerator.
Fig. 2