Dometic RM2454 Installation And Operating Instructions Manual

Dometic RM2454 Installation And Operating Instructions Manual

Refrigerator for lp-gas and electric operation
Hide thumbs Also See for RM2454:

Advertisement

REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION
RM2454
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Refer to this
manual. For assistance or additional
information consult a qualified
installer, service agency or the gas
supplier.
USA
Service Office
Dometic Corporation
509 South Poplar Street
LaGrange, IN 46761
Phone: 260-463-4858
822709202 (French 3309243.008)
INSTALLATION AND
®
OPERATING INSTRUCTIONS
Corporate Office
2320 Industrial Parkway Elkhart, IN 46515
For Service Center Assistance
Call: 800-544-4881
Contents:
Installation
Operating Instructions
Maintenance & Service
Pour votre sécurité
Si vous sentez une odeur de gaz:
1. Ouvrez les fenêtres.
2. Ne touchez à aucun interrupteur.
3. Éteignez toute flamme nue.
4. Avertissez immédiatement votre fournis-
seur de gaz.
Pour votre sécurité
Ne pas entreposer ni utiliser de l'essence ni
d'autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre
appareil.
Avertissement: Une installation, un réglage,
une modification, une réparation ou un
entretien non conforme aux normes peut
entraîner des blessures ou des dommages
matériels. Lisez attentivement le mode d'em-
ploi fourni avec l'appareil. Pour obtenir de
l'aide ou des renseignements supplémentai-
res, consultez un installateur ou un service
d'entretien qualifié ou le fournisseur de gaz.
®
Page
4
8
12
CANADA
Dometic Distribution Inc.
866 Langs Drive
Cambridge, Ontario
N3H 2N7 Canada
Phone: 519-653-4390

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM2454

  • Page 1 Corporate Office 2320 Industrial Parkway Elkhart, IN 46515 For Service Center Assistance Call: 800-544-4881 Contents: Page Installation Operating Instructions Maintenance & Service ® CANADA Dometic Distribution Inc. 866 Langs Drive Cambridge, Ontario N3H 2N7 Canada Phone: 519-653-4390...
  • Page 3 Reigniter Relay Power module cover FIG. 1 Flexible cord AUTO FIG. 2 12V DC 12 volt Terminal block Manual gas shutoff valve Inlet fitting Drain water hose Refrigerator control panel COLD CHECK Heaters Flue baffle Protection cover Screw for protection cover Burner jet COLDEST LEGEND 3-WAY AMES Model...
  • Page 4 INSTALLATION GENERAL INSTRUCTION This appliance is designed for storage of foods and storage of frozen foods and making ice. This appliance is certified under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel. The installation must conform with local codes, or in absence of local codes, the following standards as ap- plicable.
  • Page 5 VENTILATION HEIGHTS Refer to FIG. 3 page 4. Installation with roof Minimum ventilation vent and lower side vent heights in: Refrigerator Inches RM 2454 37-3/4 CLEARANCES Minimum clearances in inches to combustible materials are: G: Top K: Side Bottom 0 M: Rear N: See NOTE: Clearance “N”...
  • Page 6 INSTALLING REFRIGERATOR IN ENCLOSURE NOTE: DO NOT install the appliance directly on carpeting. Carpeting must be removed or protected by a metal or wood panel beneath the appliance, which extends at least full width and depth of the appliance. NOTE: A wood strip must be in place across the upper opening of the enclosure.
  • Page 7: Drain Water Hose

    FIG. 9 Replace the top decoration panel. Be careful not to pinch the wires behind the panel. Make sure the tabs snap back into the holes in the hinge plate. STEP 3: Two screws installed in the rear base. See FIG. 10. Failure to follow the sequence in securing the refrigerator in the enclosure can cause leakage between the frame and cabinet.
  • Page 8: Electrical Connection

    ELECTRICAL CONNECTION 120 Volts AC Connection The refrigerator is equipped with a three-prong (ground- ing) plug for your protection against shock hazards and should be plugged directly into a properly grounded three-prong receptacle. DO NOT cut or remove the grounding prong from this plug. The free length of the cord is 2 feet and therefore recommended that the re- ceptacle be located to the left side of the refrigerator (viewed from the rear) and approximately 6 inches from...
  • Page 9: Auto Mode

    START UP INSTRUCTIONS A. A continuous 12 volt DC supply must be available for the electronic control to function. B. Press the main power ON/OFF button (1) to the DOWN position. C. Press the TEMPERATURE SELECTOR button (4) until the lamp at the desired setting is illuminated. AUTO MODE 1.
  • Page 10 DESCRIPTION OF OPERATING MODES AUTO MODE When operating in the AUTO mode, the AUTO mode indicator lamp (D) will illuminate. The control system will automatically select between AC and GAS operation with AC having priority over GAS. Either the AC indicator lamp (B) or the GAS indicator lamp (C) will illuminate depending on the energy source selected by the control system.
  • Page 11: How To Use The Refrigerator

    HOW TO USE THE REFRIGERATOR FOOD STORAGE COMPARTMENT The food storage compartment is completely closed and unventilated, which is necessary to maintain the required low temperature for food storage. Consequently, foods having a strong odor or those that absorb odors easily should be covered.
  • Page 12: Refrigerator Removal

    Refer to section INSTALLATION, page 4 to 8. 3. PERIODIC MAINTENANCE To keep your Dometic refrigerator operating efficiently and safely, periodic inspection and cleaning of several components once or twice a year is recommended. A. It is important to keep the area at the back of the refrigerator clean.
  • Page 13: Troubleshooting

    C. Check the AMES control system by connecting/dis- connecting 120 volt AC power, start/stop the engine, etc. Compare the operation with the operation de- scribed in section Operating Instructions. D. The LP gas pressure should be checked and the main regulator readjusted if pressure is incorrect.
  • Page 14 RM 2454 inch 32-9/16 32-1/2 SPARE PARTS The following list is a list of commonly used parts, which should be available, if required, from your Dometic Ser- vice Center. Part No. Description 17 37 39-07/9 Heater, 175W, 12V 17 37 71-02/3...
  • Page 15 CERTIFIED VENT SYSTEM KITS REFRIGERATOR MODEL RM 2454 * Fill in “XXX” with color code numbers. For color codes, contact your supplier. For further information contact your dealer or distributor. COMPONENTS Roof Base Roof Cover Lower Side Vent PART NO. 3103633.XXX* 3103634.XXX* 3109350.XXX*...
  • Page 16 RM 2454 MO-FO 0413...

Table of Contents