  • Page 2 Aquatic Fitness System 2003 Owner’s Manual...
  • Page 3: Table Of Contents

    Up and Down Buttons ..............................20 Program Button ................................21 Clock:............................................21 Filter Cycle Start Time: ......................................21 Filter Cycle Duration:......................................21 Number of Filter Cycles:...................................... 22 Temperature Unit:........................................ 22 Heat Indicator Light ................................ 22 Dimension One Spas Icon (Logo) Button ........................22...
  • Page 4 Aquatic Fitness System 2003 Owner’s Manual Digital Display Messages..............................23 “OH” – Overheat Protection....................................23 Flashing LED on the Control Panel................................... 23 Flashing LED on the Control Panel................................... 23 Flashing Temperature on the Display................................24 ROUTINE EQUIPMENT MAINTENANCE ....................25 DRAINING YOUR AQUATIC FITNESS SYSTEM ................
  • Page 5: Important Safety Instructions

    Aquatic Fitness System 2003 Owner’s Manual Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY The following basic safety precautions should always be followed when you have installed, and are using, this electrical (and gas, in some models) equipment: Safeguard All Children At All Times. Never permit children to use this Aquatic Fitness System without adult supervision.
  • Page 6 Aquatic Fitness System 2003 Owner’s Manual Risk of Electric Shock. Install at least 5 FEET (1.5m) from all metal surfaces. As an alternative, an Aquatic Fitness System may be installed within 5 feet (1.5m) of metal surfaces if each metal surface is permanently connected by a minimum No.
  • Page 7 Aquatic Fitness System 2003 Owner’s Manual To Reduce the Risk of Injury. The use of alcohol, drugs or medication before or during Aquatic Fitness System use may lead to unconsciousness with the possibility of drowning. To Reduce the Risk of Injury. Persons suffering from obesity or with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using an Aquatic Fitness System.
  • Page 8: Hyperthermia

    Aquatic Fitness System 2003 Owner’s Manual Hyperthermia Prolonged immersion in hot water may induce hyperthermia. A description of the causes, symptoms, and effects of hyperthermia are as follows: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F, or 37° C. The symptoms of hyperthermia include dizziness, drowsiness, lethargy, and fainting.
  • Page 9: Do's And Don't's

    Aquatic Fitness System 2003 Owner’s Manual DO’S AND DON’T’S Do’s • DO read all operating instructions. • DO read, understand and follow all Safety, Danger and Warning instructions before use. • DO test water temperature with your hand before entering to be sure that it is comfortable. •...
  • Page 10: Danger Sign

    Vista, CA 92083 (760) 727-7727 Be sure to use your Serial Number whenever contacting your dealer or Dimension One Spas Inc. The Serial Number can be found on the bottom of the frame, beneath the skirt paneling, directly below the Top Side Control.
  • Page 11: Aquatic Fitness System Features

    Aquatic Fitness System 2003 Owner’s Manual Aquatic Fitness System Features Congratulations! You have purchased the finest Aquatic Fitness System available. Take the time to read these instructions carefully. When installed and maintained properly, your Aquatic Fitness System will provide many years of enjoyable, trouble-free operation.
  • Page 12: Rowing Seat

    Aquatic Fitness System 2003 Owner’s Manual Rowing Seat Additionally, a rowing area is designed into the Aquatic Fitness System for use with the HydroSport Rowing System. Swim Tether Mounts Swim Tether Mounts are located at each end of the Aquatic Fitness System.
  • Page 13: Aquatic Fitness System Equipment Pack

    Aquatic Fitness System 2003 Owner’s Manual Aquatic Fitness System Equipment Pack The Aquatic Fitness System Equipment Pack contains all of the equipment required to provide you with a safe and pleasurable swimming or aquatic exercise experience. The equipment may be located under the skirt panels or in a remote location and contains the following components: The electronic control system that governs all of the functions of Equipment Control System...
  • Page 14: Using Your Aquatic Fitness System

    Aquatic Fitness System 2003 Owner’s Manual Using Your Aquatic Fitness System Before you Start To complete the installation of your Aquatic Fitness System you must add water. Your dealer cannot complete safety checks, test equipment operation, or conduct initial training until you have added water. The Aquatic Fitness System should be filled until the water level is approximately 2 inches (5 centimeters) above the bottom of the tile line.
  • Page 15: Temperature Set Buttons

    Aquatic Fitness System 2003 Owner’s Manual Temperature Set Buttons Temperature Set Buttons: Press the “Warmer” Up Arrow button to increase the desired temperature. Press the “Cooler” Down Arrow button to decrease the temperature. The temperature set point can be adjusted in 1°F increments from 65°F to 104°F (18.3°C to 40°).
  • Page 16: Jets 2 And Jets 3 Buttons

    Aquatic Fitness System 2003 Owner’s Manual Jets 2 and Jets 3 Buttons JETS 2 and JETS 3 Buttons: Press the appropriate button once to turn on Pumps 2 or 3. The pumps work independently, thus allowing you to control the total volume of water pumped to the Swim Jets.
  • Page 17: Programming The Filtration Cycle

    Aquatic Fitness System 2003 Owner’s Manual Programming the Filtration Cycle Filtration Proper filtration is an important key to maintaining the clarity of your spa’s water. The filter system is designed for unsurpassed effectiveness at removing debris and suspensions from the water anytime the water is circulating.
  • Page 18: Filter Cycles

    Aquatic Fitness System 2003 Owner’s Manual Filter Cycles Standard Mode Standard Mode heating is automatically controlled by the loss of water temperature. If the spa water drops 2°F (1.1°C) below the set temperature, the low speed pump and the heater will automatically turn on. They will both remain on until the water temperature reaches the temperature set point.
  • Page 19: Economy Mode

    Aquatic Fitness System 2003 Owner’s Manual Economy Mode In this mode, the timer determines when the filtering and heating take place. If the LED Digital Display Window displays COL and ICE, Cool or Ice conditions have been discovered. These conditions take precedence over the Economy Mode. Heat will be applied as required by the identified condition regardless of the filter cycle.
  • Page 20: Lockout Mode

    Aquatic Fitness System 2003 Owner’s Manual Lockout Mode LOCKOUT – This special feature can be used when cleaning or changing the filter cartridge, or when doing any type of non-electrical servicing that requires the pump operation to be suspended while the work is completed. To select Lockout Mode L1, press and hold the Warmer and Cooler Buttons for three (3) seconds.
  • Page 21: Spa "Included

    Heater and Circulation Pump Control On all Dimension One Spas, when the water temperature is 1° F (.55° C) below the set temperature the heater will turn on and remain on until the water temperature rises to 1° F (.55° C) above the set temperature.
  • Page 22: Operation Of The Spa

    Using The Top Side Control Advanced microprocessor technology has been utilized to produce the Programmable Digital Control. Easy to use and understand, Dimension One Spas has put every hot tub function within fingertip control. Temperature setting, jet power control, and the hot tub light are all spa-side accessible.
  • Page 23: Led Digital Display Window

    Aquatic Fitness System 2003 Owner’s Manual LED Digital Display Window LED Digital Display Window: This window displays the actual water temperature in either F or C. It will also display time, filter cycle start time, filter cycle duration time, and the number of filter cycles. When you are setting the “target temperature”...
  • Page 24: Light Button

    Aquatic Fitness System 2003 Owner’s Manual Light Button Light Button: Push the LIGHT button once to activate the brightest setting. A second push will activate the medium setting, and a third push will activate the dimmest setting. Push the LIGHT button a fourth time to turn the light off.
  • Page 25: Program Button

    Aquatic Fitness System 2003 Owner’s Manual Program Button Program Button: The PROGRAM Button is used to set several different functions including: Programmable Item Program Button Action Clock Press & Hold 5 seconds Filter Cycle Start Time Press Filter Cycle Duration Press Number of Filter Cycles Press...
  • Page 26: Number Of Filter Cycles

    Dimension One Spas Icon (Logo) Button Dimension One Spas ICON (Logo): The time of day can be viewed by pushing the Dimension One Spas ICON logo on the far right of the control. If no other button is pushed within 5 seconds, the display will revert to the spa water temperature reading.
  • Page 27: Digital Display Messages

    OH in the display, your system has detected a high limit condition. The water temperature has reached 118° F (47.8° C). The entire system is disabled. Contact your local Authorized Dimension One Spas Dealer, or authorized service center. Flashing LED on the Control Panel DO NOT ENTER THE WATER if you see 3 flashing LEDs on the Digital Display Control.
  • Page 28: Flashing Temperature On The Display

    DO NOT ENTER THE WATER if you see a flashing Flashing Temperature on the Display temperature of 34° F or 134° F. The system has detected a Temperature Probe Failure. Contact your local Authorized Dimension One Spas Dealer, or authorized service center.
  • Page 29: Routine Equipment Maintenance

    Aquatic Fitness System 2003 Owner’s Manual Routine Equipment Maintenance Draining Your Aquatic Fitness System Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use this system unless they are supervised at all times. All models are gravity drained.
  • Page 30: Light Bulb Replacement

    Do not attempt to remove the light housing cover without the special tool. If you are not able to locate it, contact the Dimension One Spas’ Service Department to have one sent. Be sure the O-ring is not damaged and is properly in place when replacing the lens.
  • Page 31: Surface Care - Shell

    To protect your beautiful wood finish, re-stain it every 3-6 months with Dimension One Spas’ Redwood or Coastal Gray Stain, which serves as a good sealing agent for the wood. Please note that the cabinet is not warranted against reaction to natural weather conditions.
  • Page 32: Special Cold Weather Instructions

    All systems manufactured by Dimension One Spas are designed for rigorous winter use. They are insulated to keep operating costs down and to protect plumbing and equipment whenever the products are operational. Each product line incorporates freeze protection mode to maintain water circulation during freezing conditions whenever the system has proper electrical power and water level.
  • Page 33 Aquatic Fitness System 2003 Owner’s Manual Close all jets, by turning jet faces counter clockwise. 10. Put on your protective goggles in order to protect eyes from air, water, antifreeze or debris exiting the jets or drains. 11. Insert the hose of a high-pressure air blower into the filter element fitting. Some models may have 2 filters.
  • Page 34: Spring Time Startup

    Always check your system after any power failure to ensure that it is operational. Draining and not operating your system disables this feature. For additional information about winterizing your Aquatic Fitness System, please contact your local Authorized Dimension One Spas dealer.
  • Page 35: Warranty Service Information

    Aquatic Fitness System 2003 Owner’s Manual Warranty Service Information Your Aquatic Fitness System warranty gives you specific coverage. Be sure to read the enclosed warranty sheet carefully. The warranty does not cover problems arising from misuse, abuse, or neglect, and it does not cover problems caused by improper installation or “perceived”...
  • Page 36: Glossary Of Terms

    Aquatic Fitness System 2003 Owner’s Manual Glossary of Terms Term Definition Air Relief Valve Used for purging air from the filter system whenever servicing the filter, during initial startup, and whenever you drain and fill the Aquatic Fitness System. Increase or decrease the amount of air drawn through the jets. The Air Volume Controls intensity of jet action is varied by adjusting the amount of air mixed with the water forced through the jets.
  • Page 37 Aquatic Fitness System 2003 Owner’s Manual Term (Cont.) Definition Heater An 11kw 230v thermostatically controlled electric heater equipped with a high-limit temperature safety shut-off switch. If the high-limit safety switch trips, contact your authorized Aquatic Fitness System Dealer. See the Troubleshooting Guide for more information.
  • Page 38 Aquatic Fitness System 2003 Owner’s Manual Term (Cont.) Definition Skimmer Door Removes floating debris from the water surface. This inlet provides a water return path to your Aquatic Fitness System’s equipment and flow through the filter element. Slice Valves / Shutoff Valves Valves located within the Aquatic Fitness System’s internal plumbing, which are used by service personnel to shut off water flow to the heater and pumps.
  • Page 39: Troubleshooting Guide

    Aquatic Fitness System 2003 Owner’s Manual Troubleshooting Guide Heating System Symptom Problem Corrective Action Does not heat Temperature setting is too low Turn up the thermostat Dirty filter Clean filter Flow switch out of adjustment Call for service Too hot Temperature setting is to high Turn down the thermostat High limit tripped...
  • Page 40: Self-Diagnostic Control System

    Aquatic Fitness System 2003 Owner’s Manual Self-Diagnostic Control System AquaFit™, AquaFit™Dual Temp (Pool-Side), AquaPro™ Symptom Problem Corrective Action Non-functional Call your dealer for service. High Temperature Sensor: Open high temperature sensor. Heater is deactivated. Non-functional temperature sensor: Call your dealer for service. Open temperature sensor.
  • Page 41: Aquafit™Dual Temp (Spa-Side)

    Aquatic Fitness System 2003 Owner’s Manual Symptom (Cont) Problem Corrective Action No action required unless the water temperature fails to return to acceptable High temperature condition: levels – in which case, call your dealer for Do not enter the spa water. The water service.
  • Page 42 Aquatic Fitness System 2003 Owner’s Manual Symptom (Cont) Problem Corrective Action Call the dealer for service. Temperature Probe Failure: If the LED Digital Display shows 34°F or 134°F, you have an Open temperature sensor. The heater is deactivated.