Set serial DIP switch (MEI versions only) according to your serial device
requirements. Pinout information available on back of quick start.
Switch
Settings
Up/On
Down/Off
INSTALL
1, 2, or 4
Port
Note for PortServer TS P MEI series only -
In EIA-232 mode, If switch 3 is down,
9V power is provided on pin 9 (DTR).
*
If switch 3 is up, power on pin 9 is disabled
and 5V power can be enabled on pin 1 (RI)
1 2 3 4
through the software interface.
INSTALL
8 or 16
Port
Connect
Ethernet
cable
LEDs will flash during startup
Power
- steady blinking; seeking or
waiting for an IP address
Link
- on; physical network detected
10/100
- off; 10Mbit Ethernet detected,
on; 100Mbit Ethernet detected
ACT
- on; bad initialization,
off; ready,
blinking; network activity
COL
- on; Ethernet collision detected
Insert CD
RUN
Software &
Documentation
WIZARD
If you have a UNIX system and it
does not use an auto-mounter, you
will need to manually mount the CD.
See the back of this guide for UNIX
specific instructions.
© Digi International Inc., 2006.
Digi, Digi International, the Digi logo, and PortServer TS are trademarks or registered trademarks
of Digi International, Inc. in the United States and other countries worldwide.
All other trademarks are the property of their respective owners.
PortServer TS MEI
PortServer TS P MEI
PortServer TS H MEI
EIA-422/485
EIA-485
EIA-232
Full-Duplex
Half-Duplex
*
1 2 3 4
*If switch 4 is up, termination resistor
is connected.
If switch 4 is down, termination resistor
is not connected.
Connect
power
supply
PortServer TS 8
Connect serial
devices
*If you need help
with cabling,
see other side
!
You must disable
firewall/antivirus software
before running wizard.
PortServer TS 1 MEI (shown)
PortServer TS 16 MEI (shown)
PortServer TS
Connect
serial
device
*
LEDs will flash
during startup
Connect
Ethernet
cable
Follow wizard
Power cord
(PortServer TS 16
families only)
Software &
Documentation
Ethernet cable not included
Wall and brick power supply
(PortServer TS families 1/2/4/8
only)
PN:(1P)
Connect
Ethernet
cable
Power (green)
on; power supply
Status (yellow)
blinking; seeking or waiting for an
IP address - for status codes, see User's
Guide
Connect power cord
and flip power switch on
PortServer TS 16 MEI
Connect serial devices
The PortServer TS 8/16 MEI settings are configured
through the software. Complete the Quick Start Guide
and go to the User's Guide for the procedure to
configure the MEI ports. The ports are set to EIA-232
by default. If your device is not EIA-232, configure the
MEI settings immediately after completing the Quick
Start. The default settings will not harm your device,
however, we recommend configuring the MEI
settings immediately as a precaution.
Congratulations!
Configuration is complete.
Go to the User's Guide
on the CD for more
information.
Be sure to check Digi Support for
the latest firmware updates at:
http://support.digi.com
What you will need
DB-9 -RJ-45
adapter
90000687-88
B
Connect
power
supply

Advertisement

loading

Summary of Contents for Digi PortServer TS Series

  • Page 1: Quick Start Guide

    © Digi International Inc., 2006. Digi, Digi International, the Digi logo, and PortServer TS are trademarks or registered trademarks of Digi International, Inc. in the United States and other countries worldwide. All other trademarks are the property of their respective owners.
  • Page 2 DCD. This alternative can be used if DCD is not required, and DSR is needed instead. Configure the altpin through the web interface or the command line. See the User's Guide, MEI chapter or the set flow command in the Command Reference on the Digi CD under Documentation for more information about setting the altpin.

This manual is also suitable for:

Portserver ts meiPortserver ts p meiPortserver ts h meiPortserver ts