Service Hints; Technical Service - Desa HDR16PT Safety Information And Installation Manual

Unvented (vent-free) infrared gas heater
Table of Contents

Advertisement

Available languages

Available languages

CLEANING
Continued
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air or
small, soft bristled brush to clean.
BURNER PILOT AIR INLET
The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these holes
clear of dust, dirt and lint. Clean these air inlet
holes prior to each heating season. Blocked
air holes will create soot. We recommend that
you clean the unit every three months during
operation and have heater inspected yearly
by a qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store or
home center may carry compressed air in a
can. If using compressed air in a can, please
follow the directions on the can. If you don't
follow directions on the can, you could dam-
age the pilot assembly.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner, pilot for dust and dirt.
3. Blow air through the ports/slots and holes
in the burner.
4. Never insert objects into the pilot tube.
Clean the pilot assembly also. A yellow tip on
the pilot flame indicates dust and dirt in the
pilot assembly. There is a small pilot air inlet
about two inches from where the pilot flame
comes out of the pilot assembly (see Figure
26). With the unit off, lightly blow air through
the air inlet. You may blow through a drinking
straw if compressed air is not available.
Pilot Air Inlet
Figure 26 - Pilot Air Inlet
121255-01A
Pilot Assembly
www.desatech.com
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to re-
move dust.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.

TECHNICAL SERVICE

You may have further questions about instal-
lation, operation or troubleshooting. If so,
contact DESA Heating Products' Technical
Service Department at 1-866-672-6040.
When calling please have your model and
serial numbers of your heater ready.
You can also visit DESA Heating Products' tech-
nical service web site at www.desatech.com.