Outside Air And Damper Handle; Technical Service - Desa C36EMW Installation Instructions Manual

36” circulating firebox
Table of Contents

Advertisement

STEP 4: Repack insulation around gas line and into sleeve
opening.
Seal any gaps between gas line and refractory
knockout hole with refractory cement or commercial furnace
cement. Install the gas appliance or cap-off gas line if desired.
CAUTION: All gas piping and connections must be tested
for leaks after the installation is completed. After ensuring
that the gas valve is on, apply a commercial leak detection
solution to all connections and joints. Bubbles forming
show a leak. Correct all leaks at once. DO NOT USE AN
OPEN FLAME FOR LEAK TESTING AND DO NOT
OPERATE ANY APPLIANCE IF A LEAK IS
DETECTED. LEAK TESTING SHOULD BE DONE BY
A QUALIFIED SERVICE PERSON.
IF YOU WISH TO INSTALL AN UNVENTED (VENT-
FREE) GAS LOG SET, ONLY UNVENTED GAS LOG
SETS, WHICH HAVE BEEN FOUND TO COMPLY WITH
THE STANDARD FOR UNVENTED ROOM HEATERS,
ANSI Z21.11.2, ARE TO BE INSTALLED IN THIS
FIREPLACE.
NOTE: A DESA hood must be installed when using an
unvented gas log set (see accessories on page 12).
WARNING: Do not operate an unvented gas log set
in this fireplace with the chimney removed.
If you install a decorative gas appliance (vented gas log), the
decorative gas appliance must comply with the Standard for
Decorative Gas Appliance for Installation in Solid Fuel
burning Fireplaces, ANS Z21.60, Z21.84 or RGA 2-72, and
shall also be installed in accordance with the National Fuel
Gas Code, ANS Z223.1-NFPA 54 latest edition.
WARNING: If the fireplace has been used for wood
burning, the firebox and chimney must be cleaned of
soot, creosote and ashes by a qualified chimney cleaner.
Creosote will ignite if highly heated.
WARNING: When using a decorative vented gas
log, the damper must be removed or permanently
locked in the fully open position and the glass doors
must be in the fully open position.
OUTSIDE AIR AND DAMPER HANDLE OPERATION
The damper handle, which opens and closes the damper blade,
is located in the upper front face of the fireplace. Pushing the
handle in to the left of the keyway slot will free the damper
blade to automatically open. Pushing the handle in to the right
will lock the damper blade closed (see figure 25).
Figure 25
DAMPER AND AIR KIT HANDLE
The outside air kit handle is located at the left hand side of the
fireplace (see figure 25). Pulling the handle out will free the
outside air door to open. Pushing the handle in will lock the
door close.
WARNING: Risk of fire! Replace grate with DESA
model 11116 grate only. This grate has been designed
to keep the operation of your fireplace safe and
efficient.
FOR
FURTHER
INSTRUCTIONS AND WARRANTY INFORMATION,
PLEASE REFER TO YOUR HOMEOWNERS GUIDE
OR CONTACT YOUR AUTHORIZED DEALER.

TECHNICAL SERVICE

You may have questions about installation, operations, or
troubleshooting.
Department at 1-866-672-6040. When calling, have the model
number of the fireplace ready.
-
-
10
OPERATING
GUIDELINES,
If so, contact the Technical Service
For more information, visit www.desatech.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents