Technical Data - Delta Electronics DRP024V060W1BA Manual

Switch mode power supply 60w 1phase cliq ll din rail
Table of Contents

Advertisement

Technical Data

Input Data (1)
Nominal input voltage and frequency
Voltage range
Frequency Range
Nominal current
Inrush current limitation. I2t (+25°C) typ.
Mains buffering at nominal load (typ.)
Turn-on time
Internal fuse
Recommended backup fuse: Power circuit-breaker characteristic
Leakage current
Energy Star Level
Output Data (2)
Nominal output voltage U
/ tolerance
N
Setting range of the output voltage
Nominal current
De-rating above +50°C
Startup with capacitive loads
Max. power dissipation idling / nominal load approx.
Efficiency
Residual ripple / peak switching (20 MHz) (at nominal values)
Can be connected in parallel for redundancy and increased capacity
Surge voltage protection against internal surge voltages
Certification/Standards
Electrical equipment of machines
Safety transformers for switched-mode power supply units
Electrical safety (of information technology equipment)
Industrial Control Equipment
Electronic equipment for use in electrical power Installations
Safety entry low voltage
Safe isolation
Protection against electric shock
Protection against shock currents, basic requirements for protective
separation in electrical equipment
Limitation of mains harmonic currents
2/13
1/10/2011
Switch Mode Power Supply
60W1Ph
100-240VAC / 50-60Hz
85-264VAC (120 – 375 VDC)
47-63Hz
1.5A max @115VAC, 1.0A max @230VAC
< 35A @ 230VAC
> 20ms @ 115VAC, > 125ms @ 230VAC
< 3.0sec.
T 3.15 AH / 250V
6A, 10A or 16A : B
< 1mA
V
24VDC±2%
24-28VDC
2.5A
> 50°C (2.5% / °C)
Max 8,000µF at 25°C
7.4W
> 89% typical.
< 50mV / < 150mVpp.
YES with ORing Diode or Redundancy module
YES
IEC60204-1 (overvoltage category III)
TUV BAUART to EN60950-1, UL/C-UL recognized to
UL60950-1, CSA C22.2 No. 60950-1,
CB scheme to IEC60950-1
UL / C-UL Listed UL508 and CSA C22.2 No. 107.1-01, CSA to
CSA C22.2 No.107.1-01 (file no. 181564)
EN50178 / IEC62103
PELV (EN60204), SELV (EN60950)
DIN.VDE 0100-410
DIN 57100-410
VDE 0106-101
DIN57100-410
DRP024V060W1BA
Rev: 00,

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents