POST error codes

In the following index, "X" can represent any number.
POST Error Code
000
SCSI Adapter not enabled.
02X
08X
Check SCSI terminator
installation.
101
System board interrupt
failure.
102
System board timer error.
106
110
System board memory
parity error.
111
I/O channel parity error.
114
Adapter ROM error.
129
Internal cache test error.
151
Real-time clock failure.
161
Bad CMOS battery.
PC 300 - 6563/6593/6564/6574 Aptiva - 2178/2198
FRU/Action
1. Verify adapter device
and Bus Master fields
are enabled in PCI
configuration
program. See
documentation
shipped with
computer.
1. SCSI Adapter
1. SCSI Cable
2. SCSI Terminator
3. SCSI Device
4. SCSI Adapter
1. System Board
1. System Board
1. System Board
1. Memory Module
2. System Board
1. Reseat adapters
2. Any Adapter
3. System Board
1. Adapter Memory
2. System Board
1. Processor
2. L2 Cache Memory
3. System Board
1. System Board
1. Run Setup
2. CMOS Backup Battery
(See page "Safety
information" on
page 434.)
3. System Board