IMI CORNELIUS INC. One Cornelius Place Anoka. MN 55303-6234 Telephone (800) 238--3600 Facsimile (612) 422--3246 INSTALLATION INSTRUCTIONS KIT, P/N 2306 For installing Scotsman Model CM450, 500, & 650 Series Ice Makers on Remcort Model DB200 Series Ice/ Drink dispenser. 1. Bin Level Control Locate and drill three (3) 5/16”diameter holes (Ref.
Page 2
ROUTE ICEMAKER BIN LEVEL THERMOSTAT CAPILLARY TUBE AS SHOWN. INSTALL ON HOPPER AS SHOWN IN FIG. 1 ICEMAKER TO BE FLUSH WITH BACK EDGE OF COVER. APPLY RTV AROUND INSIDE OF ICEMAKER OUTLINE ON DISPENSER COVER TO FORM A SEAL. ADD ADHESIVE BACKED GAS- KET STRIPS TO REMOVABLE LID.
Page 3
ICEMAKER TOP- VIEW FRONT WALL OF HOPPER THERMOSTAT CAPILLARY TUBE LOCATE AND ADD CLAMP HOLE IF NEEDED TO RETAIN CAPILLARY TUBING 4--5/8 15” 1” DRILL 5/16 DIA. HOLES FOR 8--32 WELD NUT INSERT 8-32 WELL NUTS INTO 5/16 DIA. HOLES, TIGHTENING SCREWS WILL SECURE 1--5/8 CAPILLARY TUB-...