Summary of Contents for Hitachi CM1711MET-PCMP

  • Page 1 MET-PCMP GEBRUIKSAANWIJZING . ..35 MANUEL UTILISATEUR . . .s EasyMenu ! with EasyMenu is HITACHI’s On Screen Display function for easy operation. READ THE INSTRUCTIONS INSIDE CAREFULLY. KEEP THIS USER MANUAL FOR FUTURE REFERENCE. EPA POLLUTION PREVENTER For future reference, record the serial This monitor is Energy Star compliant number of your colour monitor.
  • Page 3: Table Of Contents

    ENGE COLOUR MONITOR CM171 1 MET- USER MANUAL USH = PCMP NOTICE : The information in this document is subject to change without notice. The manufacturer assumes no responsibility for any errors that may appear in this manual. FEATURES ..........CAUTIONS .
  • Page 4 -ENG provided Sharpest Focus and Highest Contrast flat screen CRT with anti-glare, dynamic focus circuit, dark glass, and an INVAR shadow mask gives the sharpest focus and highest contrast to minimize eye fatigue. Wide-range Multi-Scanning Automatic scanning and automatic adjustment to conform with a wide range of scanning frequencies and user requirements.
  • Page 5: Cautions

    NEVER REMOVE THE REAR COVER I ENGZ USH = The rear cover MUST be removed only by authorized service personnel. This colour monitor contains high voltage components. BE CAREFUL OF STATIC ELECTRICITY ON CRT SURFACE ! To prevent electrical shock by the static electricity on the CRT surface, disconnect the power cord at least 30 SECONDS AFTER turning off the power.
  • Page 6: Installation

    Install the monitor in the following way, taking care to maintain safety. EF;z 1. Installation Install the monitor on a horizontal base. Front Cover CRT Surface Tilt & Swivel Base I FRONT VIEW Rear Cover AC Inlet Signal Input CoYector REAR VIEW A NOTICE INSTALL THE UNIT IN ADEQUATE ENVIRONMENT !
  • Page 7: Power Cord Connection

    KEEP IN A WELL VENTILATED PLACE ! DO NOT cover this monitor or place anything against any sides (not only top, right and left side but also rear and bottom side) of unit. Ventilation holes are provided at all sides of the rear cover to prevent the temperature from rising.
  • Page 8 FOR THE CUSTOMERS IN U.K. THIS PRODUCT IS SUPPLIED WITH A TWO PIN MAINS PLUG FOR USE IN MAINLAND EUROPE. FOR THE U.K. PLEASE REFER TO THE NOTES ON THIS PAGE. =ENG - USH IMPORTANT FOR UNITED KINGDOM WORDING FOR CLASS I EQUIPMENT INSTRUCTION BOOKS AND LABELS The mains lead on this equipment is supplied with a moulded plug incorporating a fuse, the value of which is indicated on the pin face of the plug.
  • Page 9 3. Signal Input Connection Connect the Signal Input Connector ENGe LISH - to the D-Sub Mini IBpin signal output terminal of the host computer. b’ to the host computer Q I g REAR VIEW Signal Input Connector l If the graphics board supplies more than one type of sync. signal, the sync. signal type will be automatically selected by the monitor, with the priority shown in the following table.
  • Page 10: Standard Settings

    Microprocessor-based preset functions can store 20 sets of geometry settings including the standard settings. Below listed preset modes. The following industrial standard settings have been preprogrammed by the factory. NOTE w Input signals with approximately the same frequencies may be regarded as the same signal. n The following horizontal timing conditions are recommended.
  • Page 11 - Control Panel p Power LED -Function LED ‘p--l~Jj [-=-g-J F&T-J ADJUST DEGAUSS F”t;;;N +fOR~ Switches Switches Switch Pagb9 Page 9 ‘POWER ON/OFF” “STORE Page s-t I ‘ADJUSTMENT = page 12 ‘DEGAUSSING POWER ON/OFF Press the POWER switch 0, to switch the power ON/OFF. &2 H When power is ON, the Power LED lights on green.
  • Page 12 ADJUSTMENT (others) =aNG You can adjust the items shown in the following table, as show; below. - USH 1. Press the FUNCTION switch. The Function LED will light, and the EasyMenu will appear. 2. Select the item by the SELECT switches. The selected item is indicated by magenta icon on the EasyMenu.
  • Page 13 ‘:.U” for Colour Select is not available before an adjustment is made by the user. There are no factory settings of selects the previous colour mode ‘.-.U”. Refer to Page 17 ‘STORE”. n When the selected colour B’ reached to its maximum or makes the selected minimum end and you still colour weaker.
  • Page 14: Operation

    STORE -:;f Press the STORE switch, to store the currently adjusting data as follows STORED fnllnwc Storing Condition Item Restoring Condition When the monitor detects One setting is allowed for each video mode. H.Position You can store maximum 20 sets of geometry the same video mode.
  • Page 15: Video Muting

    SIGNAL STATUS When the monitor has detected the change of the signal input condition, the ENG- LISH - monitor will indicate the condition automatically, as follows. Condition Indication Sample of ‘EasyMenu” When the monitor The EasyMenu indicates the horizontal frequency and vertical frequency. detects proper signal.
  • Page 16: Power Saving System

    Et;f This monitor complies with VESA, Nutek, and Energy Star power saving requirements. The power saving system works only when used with VESA DPMS compliant PC’s and/or graphic controllers. e This monitor complies with VESA DDC1/2B specifications. Plug & Play is a system with computer, peripherals (including monitors), and operating system.
  • Page 17: Specifications

    17 inches picture tube, Anti-Reflection coat, ENGS USH - 0.22 mm (optional 0.24 mm) horizontal dot pitch, lnvar shadow mask, Black matrix, Short persistence phosphors. Input Signal : 0.7 Vp-p, Analog Video : Separate H, V or Composite H/V Sync. lTL level (optional Sync.