Hitachi L100-M Series Addendum Manual page 19

Hide thumbs Also See for L100-M Series Addendum:
Table of Contents

Advertisement

L100-M Series inverters add the following 6 options to the 15 option codes for standard
L100 inverter intelligent inputs:
Option
Terminal
Function Name
Code
Symbol
20
STA
START
(3-wire interface)
21
STP
STOP
(3-wire interface)
22
F/R
FWD, REV
(3-wire interface)
27
UP
Remote Control
UP Function (motor-
ized speed pot.)
28
DWN
Remote Control
DOWN Function
(motorized speed
pot.)
31
OPE
Operator Control
Input Function Summary Table
ON
Starts the motor rotation
OFF
No change to present motor status
ON
Stops the motor rotation
OFF
No change to present motor status
ON
Selects the direction of motor rotation: ON =
FWD. While the motor is rotating, a change of
F/R will start a deceleration, followed by a
change in direction.
OFF
Selects the direction of motor rotation:
OFF =REV.
While the motor is rotating, a change of F/R will
start a deceleration, followed by a change in
direction.
ON
Accelerates (increases output frequency) motor
from current frequency
OFF
No change to output frequency
ON
Decelerates (decreases output frequency) motor
from current frequency
OFF
No change to output frequency
ON
Forces the source of the output frequency setting
(A_01) and the source of the RUN command
(A_02) to be from the digital operator
OFF
Source of output frequency set by (A_01) and
source of run command set by (A_02) is used
L100-M Inverter
Description
19

Hide quick links:

Advertisement

Table of Contents
loading