4.2.53 Exit Gate Solenoid

(See "Exit Lower Chute" on page -277)

4.2.53.1 Removal

1. Remove the Fuser Full Cover. ("Fuser Full Cover" on page -138)
2. Disconnect J210 from the Exit Gate Solenoid.
3. Remove the wire harness from the harness clips.
4. Remove the two screws securing the Exit Gate Solenoid to the
Offset Assembly, and remove the Solenoid.
Figure 4-68. Removal of Exit Gate Solenoid
Rev.B
Chapter 4

4.2.53.2 Installation

1. Position the Exit Gate Solenoid so the wire harness faces up.
2. Reinstall the Solenoid onto the Offset Assembly, making sure the
crossbar of the solenoid plunger latches onto the Solenoid Link.
3. Use two screws to secure the Solenoid to the Assembly.
4. Reconnect J210.
5. Secure the wire harness to the harness clips.
6. Reinstall the Fuser Full Cover. ("Fuser Full Cover" on page -138)