2.2 NMEA Input Command
. Set Serial Port ID:100 Set PORTA parameters and protocol
A)
This command message is used to set the protocol(SiRF Binary, NMEA, or
USER1) and/or the communication parameters(baud, data bits, stop bits, parity).
Generally,this command would be used to switch the module back to SiRF Binary
protocol mode where a more extensive command message set is available. For
example,to change navigation parameters. When a valid message is received,the
parameters will be stored in battery backed SRAM and then the receiver will restart
using the saved parameters.
Format:
$PSRF100,<protocol>,<baud>,<DataBits>,<StopBits>,<Parity>*CKSUM
<CR><LF>
<protocol>
<baud>
<DataBits>
<StopBits>
<Parity>
Example 1: Switch to SiRF Binary protocol at 9600,8,N,1
$PSRF100,0,9600,8,1,0*0C<CR><LF>
Example 2: Switch to User1 protocol at 38400,8,N,1
$PSRF100,4,38400,8,1,0*38<CR><LF>
**Checksum Field: The absolute value calculated by exclusive-OR the
**<CR><LF>
8 data bits of each character in the Sentence,between, but
excluding "$" and "*". The hexadecimal value of the most
significant and least significant 4 bits of the result are convertted
to two ASCII characters (0-9,A-F) for transmission. The most
significant character is transmitted first.
0=SiRF Binary, 1=NMEA, 4=USER1
1200, 2400, 4800, 9600, 19200, 38400
8,7. Note that SiRF protocol is only valid f8
Data bits
0,1
0=None, 1=Odd, 2=Even
: Hex 0D 0A