WARRANTY
All Hanna Instruments meters are warranted
for two years against defects in workmanship
and materials when used for their intended pur-
pose and maintained according to instructions.
The probes are warranted for a period of
six months.
This warranty is limited to repair or replacement
free of charge. Damages due to accident, mis-
use, tampering or lack of prescribed maintenance
are not covered.
If service is required, contact the dealer from
whom you purchased the instrument. If under
warranty, report the model number, date of pur-
chase, serial number and the nature of the prob-
lem. If the repair is not covered by the warranty,
you will be notified of the charges incurred. If the
instrument is to be returned to Hanna Instru-
ments, first obtain a Returned Goods Authoriza-
tion Number from the Customer Service depart-
ment and then send it with shipment costs pre-
paid. When shipping any instrument, make sure it
is properly packaged for complete protection.
All rights are reserved. Reproduction in whole or
in part is prohibited without the written consent of
the copyright owner.
Dear Customer,
Thank you for choosing a Hanna Instruments
product.
Please read this instruction manual care-
fully before using the instrument. If you need
additional technical information, do not hesi-
tate to e-mail us at tech@hannainst.com
This instrument is in compliance with the
directives.
PRELIMINARY EXAMINATION
Remove the instrument from the packing
material and examine it carefully to make
sure that no damage has occurred during
shipment. If noticeable damage is evident,
notify your dealer.
Note: Save all packing material until you
are sure that the instrument func-
tions correctly. All defective items
must be returned in the original
packing together with the supplied
accessories.
GENERAL DESCRIPTION
HI 99131 is a portable, microprocessor-
based pH and temperature meter with a
special probe.
The HI 62911 pH electrode has been spe-
cially designed and fully shielded for appli-
cations in plating baths. The titanium elec-
trode body acts like a Faraday cage, and
allows stable readings even in samples
where strong electrical fields are involved.
Moreover, a built-in temperature sensor al-
lows simultaneous pH and temperature
readings and a mini amplifier renders mea-
surements impervious to noise and elec-
trical interferences.
Each meter is supplied complete with:
HI 62911 pH/temperature probe
calibration & cleaning solution sachets
3x1.5V AA alkaline batteries
instruction manual
rugged carrying case
LCD DESCRIPTION
1. Automatic Temperature Compensation
indicator
2. Stability indicator
3. Battery percentage
4. pH calibration indicator
5. Low battery indicator
6. Selectable temperature unit
7. Secondary display
8. Primary display
9. Measuring unit for primary display
ACCESSORIES
HI 62911
Amplified pH electrode with
built-in temperature sensor,
DIN connector & titanium cage
working as matching pin
HI 7004L
pH 4.01 buffer solution, 500 mL
HI 7006L
pH 6.86 buffer solution, 500 mL
HI 7007L
pH 7.01 buffer solution, 500 mL
HI 7009L
pH 9.18 buffer solution, 500 mL
HI 7010L
pH 10.01 solution, 500 mL
HI 70300L
Storage solution, 500 mL
HI 7061L
Cleaning solution, 500 mL
HI 710007
Blue shockproof rubber boot
HI 710008
Orange shockproof rubber boot
HI 721312
Rugged carrying case
HI 76405
Electrode holder
SPECIFICATIONS
Range
-2.00 to 16.00 pH
-5.0 to 105.0°C / 23.0 to 221.0°F
Resolution
0.01 pH
0.1°C / 0.1°F
Accuracy
(@20°C)
±0.02 pH
±0.5°C up to 60°C; ±1°C outside
±1°F up to 140°F; ±2°F outside
Typical EMC
±0.02 pH
Deviation
±0.2°C or ±0.4°F
Temperature
Automatic
Compensation
pH Calibration
Automatic, 1 or 2 point
with 2 sets of memorized buffers
(pH 4.01/7.01/10.01 or 4.01/6.86/9.18)
Probe
HI 62911
(included)
amplified pH probe with built-in
temperature sensor and titanium cage
working as matching pin
Battery Type
3 x 1.5V AA / IEC LR6
Battery Life
Approx. 1500 hours
Auto-off
After 8 minutes of non-use
Environment
0 to 50°C (32 to 122°F);
RH max 100%
Dimensions 150x80x36 mm (5.9x3.1x1.4")
Weight
210 g (7.4 oz.)
To clean the meter, it is recommended to use water.
Hanna Instruments reserves the right to
modify the design, construction and appear-
ance of its products without advance notice.
IST99131R3
07/05

Advertisement

loading

Summary of Contents for Hanna Instruments HI 99131

  • Page 1 Instruction Manual Dear Customer, LCD DESCRIPTION SPECIFICATIONS Thank you for choosing a Hanna Instruments product. HI 99131 Please read this instruction manual care- Range -2.00 to 16.00 pH fully before using the instrument. If you need -5.0 to 105.0°C / 23.0 to 221.0°F...
  • Page 2 OPERATIONAL GUIDE pH MEASUREMENT & CALIBRATION After 1 second the meter automatically returns METER SETUP to the normal measuring mode. If a single-point calibration with buffers pH 7.01 To connect the probe • Make sure the meter has been calibrated be- Setup mode allows the selection of the tempera- or 6.86 is desired, then after the calibration fore use.