66
Sabre Owner's Guide
Error
"ERROR: Table Bounds
Violation -X" (or +X, -Y, +Y)
"Error: Table protect"
"FAULT IN X AXIS"
"FAULT IN Y AXIS"
"FAULT IN Z AXIS"
"PLOT DATA COMMAND"
"SPINDLE I/O FAILURE"
"UART Card Not Found"
"UART OVERRUN"
"X AXIS"
"Y AXIS"
"Z AXIS"
"X ENCODER/MOTOR"
"Y ENCODER/MOTOR"
"Z ENCODER/MOTOR"
Cause
G-code command attempted
to move outside of table active
job area.
Depth of cut will cut into table
surface.
Motor servo amplifier fault.
Illegal host GSPGL command
received.
Spindle Controller is not
turned on.
Attempt to turn on spindle
without a tool.
Spindle Controller failure.
Could not locate UART card.
Host communication not
responding to flow control.
Limit switch was tripped.
Could not move to 0,0 position
while Orienting.
Servo amplifier exceeded
maximum position error.
Encoder count indicates
insufficient or excess motion.
Remedy
Modify job so that all
movement stays within
active job area.
Adjust depth of cut or
material thickness.
Turn Table Protect OFF.
Check servo amplifier
wiring/circuitry.
Verify job type is "Gerber".
Make sure ART Path version
is compatible with router
version.
Make sure spindle controller
is on.
Install tool before turning on
spindle.
Check spindle controller
error codes.
Make sure UART card is
installed firmly into
connector and that all
connections are properly
made.
Make sure host
communication serial port is
configured for proper flow
control.
Power cycle and re-orient
router.
Check for obstruction to axis
movement.
Do not move carriage
beyond active job area.
Check Emergency Stop
cable/wiring.
Check
wiring/encoder/motor.
Ensure that rear and/or
right Limit Switches are not
engaged at power-up or
have failed during job.
Check Emergency Stop
cable/wiring.