Checking The Direction Of Rotation Of The Coupling-Positioning Actuator; Changing The Direction Of Rotation Of The Coupling-Positioning Actuator; Checking The Direction Of Rotation Of The Direct-Current Positioning Actuator; Changing The Direction Of Rotation Of The Direct-Current Positioning Actuator - DURKOPP ADLER 367 Installation Instructions Manual

Table of Contents

Advertisement

6.9.3
Checking the direction of rotation with the VD552KV/6F82FA coupling-positioning actuator
6.9.4
Changing the direction of rotation with the VD552KV/6F82FA coupling-positioning actuator
6.9.5
Checking the direction of rotation with the DC1600/DA82GA direct-current positioning actuator
6.9.6
Changing the direction of rotation with the DC1600/DA82GA direct-current positioning actuator
The direction of rotation of the coupling-positioning actuator
(three-phase motor) depends on its connection to the three-phase
supply. After connecting it to the three-phase supply the first
commissioning stage must be to check the direction of rotation.
Proceed as follows:
The proximity switch must be fitted. See section 6.7.
The proximity-switch plug must be plugged in. See figure page 20.
Do not plug in the 37-pole plug of the sewing machine.
Turn on the main switch (motor-protection switch).
Because the 37-pole plug is not plugged in, no valid Autoselect
resistance is recognised and the maximum rotation speed is
limited.
Push the pedal slightly forward; the drive rotates; check the
direction of rotation.
If the sewing drive rotates the wrong way, the phases on the terminals
of the mains connection of the sewing drive 2 must be reversed. This is
done as follows:
Turn off the main switch. and remove the mains plug.
Reverse two of the three phase conductors in the sewing-drive
mains connection.
Insert the mains plug and turn on the main switch.
Check the direction of rotation (see section 6.6.3).
The direction of rotation of the direct-current positioning actuator is
factory-set to right-to-left by entering the value 1 in parameter F-161.
Even so, the first commissioning stage must be to check the direction
of rotation. Proceed as follows:
The proximity switch must be fitted. See section 6.7.
The plugs of the set-point generator, commutation switch, proximity
switch and operating panel must be plugged in. See figure page 20.
Do not plug in the 37-pole plug of the sewing machine.
Turn on the main switch.
The operating panel displays "Info A5", which means that no valid
Autoselect resistance is recognised and the maximum rotation
speed is therefore limited.
Push the pedal slightly forward; the drive rotates; check the
direction of rotation.
Replace the 37-pole plug of the machine head.
If the sewing drive rotates the wrong way, technician-level parameter
F-161 must be set to the value 1.
For the V810 operating panel see section 6.11.4
For the V820 operating panel see section 6.11.5
Caution !
After a change in the direction of rotation the positions must be
reset. See section 6.10.
23