HP Xw25p - ProLiant - Blade Workstation Overview

Hp bladesystem p-class system overview and planning
Hide thumbs Also See for Xw25p - ProLiant - Blade Workstation:
Table of Contents

Advertisement

Quick Links

HP BladeSystem p-Class System Overview and Planning
Introduction......................................................................................................................................... 3
Executive summary............................................................................................................................... 3
HP BladeSystem modular architecture key benefits ............................................................................... 4
HP BladeSystem manageability key benefits ........................................................................................ 5
HP BladeSystem overview ..................................................................................................................... 6
Hardware components ......................................................................................................................... 9
ProLiant BL20p and BL25p series server blades ................................................................................. 10
ProLiant BL30p and BL35p series server blades ................................................................................. 11
ProLiant BL40p and BL45p Server Blades .......................................................................................... 12
ProLiant BL p-Class server blade SAN connectivity.............................................................................. 14
FC connectivity with ProLiant BL40p server blades .......................................................................... 16
HP BladeSystem p-Class Server Blade Enclosure ................................................................................ 17
HP BladeSystem p-Class Blade Sleeve............................................................................................... 19
HP BladeSystem p-Class network interconnect options ........................................................................ 20
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class .................................................. 21
ProLiant BL p-Class GbE2 Interconnect Switch ................................................................................ 22
ProLiant BL p-Class GbE Interconnect Switch .................................................................................. 23
ProLiant BL p-Class RJ-45 Patch Panel ............................................................................................ 25
ProLiant BL p-Class RJ-45 Patch Panel 2 ......................................................................................... 26
HP BladeSystem p-Class power subsystem ............................................................................................ 27
Enclosure-based power ................................................................................................................... 27
Rack-centralized power................................................................................................................... 27
Power supplies ........................................................................................................................... 27
Power distribution....................................................................................................................... 28
HP BladeSystem p-Class 1U and 3U power subsystem features............................................................ 30

Advertisement

Table of Contents
loading

Summary of Contents for HP Xw25p - ProLiant - Blade Workstation

  • Page 1: Table Of Contents

    HP BladeSystem p-Class System Overview and Planning Introduction............................3 Executive summary..........................3 HP BladeSystem modular architecture key benefits ................4 HP BladeSystem manageability key benefits ..................5 HP BladeSystem overview ........................6 Hardware components ......................... 9 ProLiant BL20p and BL25p series server blades ................. 10 ProLiant BL30p and BL35p series server blades .................
  • Page 2 HP BladeSystem p-Class Diagnostic Station................... 31 HP BladeSystem p-Class diagnostic and local I/O cables ..............32 HP BladeSystem Management Software overview ................33 HP BladeSystem p-Class operating system installation options.............. 34 Operating system support ....................... 34 HP ProLiant Essentials Rapid Deployment Pack................... 35 HP Systems Insight Manager ......................
  • Page 3: Introduction

    Introduction This white paper provides an overview of the HP BladeSystem p-Class solution. This solution includes: • Server blades • Server blade enclosures • Network interconnect options • Power subsystem components • Management tools In addition to this document, HP recommends referring to the HP BladeSystem Best Practices Guide and the HP BladeSystem Common Procedures Guide when planning and setting up a an HP BladeSystem solution.
  • Page 4: Hp Bladesystem Modular Architecture Key Benefits

    HP BladeSystem modular architecture key benefits • Rapid deployment/redeployment saves valuable time – Server blades and interconnect switches can be installed and ready for immediate automated provisioning – Easy access to most pluggable components from the front of the rack, including server blades, hot-plug hard drives, and interconnect options –...
  • Page 5: Hp Bladesystem Manageability Key Benefits

    HP BladeSystem manageability key benefits • Quickly configure both server blades and interconnect switches from a centralized deployment console using HP ProLiant Essentials Rapid Deployment Pack (RDP). – Configure tens to hundreds of server blades simultaneously in a fraction of the time required to configure conventional servers using multicasting –...
  • Page 6: Hp Bladesystem Overview

    HP BladeSystem overview Figure 1 shows an HP BladeSystem p-Class Server Blade Enclosure. Figure 1. HP BladeSystem standard server blade enclosure Table 1. Server Blade Components Item Description HP BladeSystem p-Class Interconnects (2) in a server blade enclosure (Interconnect Switch shown) ProLiant BL40p Server Blade ProLiant BL45p Server Blade ProLiant BL20p or BL25p Server Blades...
  • Page 7 Figure 2 shows an HP BladeSystem p-Class 1U Power Enclosure installation. Figure 2. HP BladeSystem p-Class Enhanced Server Blade Enclosure and 1U Power Enclosure Table 2. HP BladeSystem p-Class Enhanced Server Blade Enclosure and 1U Power Enclosure Item Description Enhanced server blade enclosure 1U power enclosure with power supplies...
  • Page 8 Figure 3 shows an HP BladeSystem p-Class 3U power subsystem installed in a 42U rack. Figure 3. HP BladeSystem 3U Power Enclosures and power distribution components in a 42U rack. Table 3. Power Subsystem Components Item Description Hot-plug power supplies in two 3U power enclosures Power distribution (scalable bus bars shown)
  • Page 9: Hardware Components

    Hardware components The HP BladeSystem p-Class solution consists of the following: • Server blades • Server blade enclosures • Network interconnects • Power subsystem Table 4. HP BladeSystem Required Components Required Function Components Server blade Server blades contain one or more processors, memory, internal and external storage options, and integrated management.
  • Page 10: Proliant Bl20P And Bl25P Series Server Blades

    ProLiant BL20p and BL25p series server blades The ProLiant BL20p and BL25p series Server Blades are ideal for infrastructure and enterprise applications, including: • Web • E-commerce • Server-based computing • AV and streaming media • Messaging front-end and mobility •...
  • Page 11: Proliant Bl30P And Bl35P Series Server Blades

    ProLiant BL30p and BL35p series server blades The ProLiant BL30p and BL35p Server Blades are ideal for enterprise and high-performance computing applications, including: • High-performance technical computing applications • Web • E-commerce • Server-based computing • Messaging front-end Figure 5. ProLiant BL30p Server Blade Table 6.
  • Page 12: Proliant Bl40P And Bl45P Server Blades

    ProLiant BL40p and BL45p Server Blades The ProLiant BL40p Server Blade is ideal for the following applications: • Medium to large enterprise databases • Messaging and collaboration • IPC Clustering/Failover Clustering • E-commerce • Server consolidation • Enterprise Resource Planning (ERP) •...
  • Page 13 Figure 7. ProLiant BL45p Server Blade Table 7. Features of the ProLiant BL40p and ProLiant BL45p Server Blade ProLiant BL40p Server Blade ProLiant BL45p Server Blade Processor Up to four Intel Xeon processors Up to four AMD Opteron 800 Series processors Internal Up to four universal hot-plug SCSI hard drives Up to two universal hot-plug SCSI hard drives...
  • Page 14: Proliant Bl P-Class Server Blade San Connectivity

    ProLiant BL p-Class server blade SAN connectivity The ProLiant BL p-Class server blades are optimized for HP StorageWorks arrays, and can attach to select third-party SAN solutions. In addition, the server blades can integrate with "fused" NAS and SAN configurations, providing the ability to work in file and block environments seamlessly. HP StorageWorks arrays include: •...
  • Page 15 Figure 8. BL20p Dual Port FC Mezzanine Card (installed) Figure 9. BL25p/BL45p Dual Port FC Adapter Figure 10. The BL30p/BL35p Dual Port FC Adapter (installed)
  • Page 16: Fc Connectivity With Proliant Bl40P Server Blades

    FC connectivity with ProLiant BL40p Server Blades ProLiant BL40p Server Blades have two external PCI-X slots for use with standard FC HBAs. When configuring ProLiant BL40p Server Blades with FC HBAs, the FC signals are not routed through the signal backplane. Refer to the documentation included with the ProLiant BL40p Server Blade for details.
  • Page 17: Hp Bladesystem P-Class Server Blade Enclosure

    FC port aggregation is required to accommodate the increased number of server FC HBA ports and to maintain compatibility with the available enclosure backplane signals and interconnect ports. The p- Class sleeve aggregates the four paths from two ProLiant BL30p or ProLiant BL35p Server Blades into two physical paths.
  • Page 18 Figure 12 is a front view of the HP BladeSystem p-Class Blade Enclosure. Figure 12. Server blade enclosure front view Features of the server blade enclosure include: • Management communication—The server blade management module reports thermal, power, and protection fuse events to all server blades in the blade enclosure. The management module also facilitates power sharing across enclosures and provides asset and inventory information.
  • Page 19: Hp Bladesystem P-Class Blade Sleeve

    Figure 13 is a rear view of the HP BladeSystem p-Class Enhanced Server Blade Enclosure. Figure 13. Enhanced server blade enclosure rear view HP BladeSystem p-Class Blade Sleeve The HP BladeSystem p-Class Sleeve is required to support ProLiant BL30p and ProLiant BL35p Server Blades in the enhanced server blade enclosure.
  • Page 20: Hp Bladesystem P-Class Network Interconnect Options

    HP BladeSystem p-Class network interconnect options Each server blade enclosure must be configured with a pair of network interconnects. These interconnects slide into the front of the blade enclosure and collect Ethernet and FC (except ProLiant BL40p Server Blades) signals from all the installed server blades. Figure 15.
  • Page 21: Cisco Gigabit Ethernet Switch Module For Hp Bladesystem P-Class

    Table 9. HP BladeSystem p-Class interconnect options Interconnect Option FC Pass Through Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class HP BladeSystem p-Class GbE2 Interconnect Switch HP BladeSystem p-Class GbE Interconnect Switch HP BladeSystem p-Class RJ-45 Patch Panel HP BladeSystem p-Class RJ-45 Patch Panel 2 Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class The CGESM is a 24-port Gigabit Ethernet Switch that significantly reduces the number of Ethernet network cables needed for each server blade enclosure.
  • Page 22: Proliant Bl P-Class Gbe2 Interconnect Switch

    Each CGESM reduces up to 16 internal server blade network NIC ports to six external Ethernet ports. Because each external Ethernet port can communicate to all the server blades, as few as one external port per enclosure may be used to connect to your network. In addition to providing up to 32-to-1 network cable reduction per server blade enclosure, the CGESM kit offers the following features: •...
  • Page 23: Proliant Bl P-Class Gbe Interconnect Switch

    The GbE2 Interconnect Kit contains two hot-plug, fully managed, layer 2 GbE2 Interconnect Switches and two LAN interconnect modules. The GbE2 Interconnect Kit is available with either copper-based (CgbE) or fiber-based (FgbE) uplinks. Each GbE2 Interconnect Switch reduces up to 16 internal server blade network NICs ports to six external Ethernet ports.
  • Page 24 Figure 18. GbE Interconnect Switch components Table 12. GbE Interconnect Switch Components Item Description GbE Interconnect Switch GbE LAN Interconnect Module In addition to providing up to 32 FC to 1GB network cable reduction per server blade enclosure, the GbE Interconnect kit offers the following features: •...
  • Page 25: Proliant Bl P-Class Rj-45 Patch Panel

    ProLiant BL p-Class RJ-45 Patch Panel The RJ-45 Patch Panel brings all server blade NIC signals out as individual RJ-45 connectors. Figure 19. RJ-45 Patch Panel components Table 13. RJ-45 Patch Panel Components Item Description RJ-45 Patch Panels RJ-45 Interconnect Module (10-connector) RJ-45 Interconnect Module (6-connector) Features of the RJ-45 Patch panel include: •...
  • Page 26: Proliant Bl P-Class Rj-45 Patch Panel 2

    ProLiant BL p-Class RJ-45 Patch Panel 2 The RJ-45 Patch Panel 2 functions as an Ethernet pass-through and enables pass-through functionality for FC signals from all server blades configured with internal FC adapter options. Figure 20. RJ-45 Patch Panel 2 components Table 14.
  • Page 27: Hp Bladesystem P-Class Power Subsystem

    HP BladeSystem p-Class power subsystem HP provides two power subsystem alternatives to accommodate various environments and customer needs. These two options are enclosure-based power and rack-centralized power. All server blades, interconnect options, and management tools are fully compatible with either power subsystem. Enclosure-based power The new HP BladeSystem p-Class 1U Power Enclosure provides hot-plug, fully redundant power for a single server blade enclosure containing any mix of server blades and interconnects.
  • Page 28: Power Distribution

    HP offers two models of 3U power enclosure that are designed to meet installation power demand and redundancy requirements, depending on the number and type of server blades you plan to deploy: • Single-phase HP BladeSystem 3U p-Class Power Enclosure (holds up to four power supplies) •...
  • Page 29 Table 15. HP BladeSystem p-Class Power Distribution Options Solution Power Enclosures Server Blade Enclosures Maximum Rack Space Supported Supported Occupied Scalable bus bar Mini bus bar Power bus box 1. To attach two power enclosures to a mini bus bar, the Dual Power Input Kit for Mini Bus Bar option is required. 2.
  • Page 30: Hp Bladesystem P-Class 1U And 3U Power Subsystem Features

    Table 16. Scalable and Mini Bus Bars Item Description Scalable bus bars 3U power enclosures Dual Power Input Kit for Mini Bus Bar Mini bus bars HP BladeSystem p-Class 1U and 3U power subsystem features • Availability—high availability, fully redundant configurations, including hot-plug redundant power supplies, redundant AC inputs, and a hot-plug power management module that operates independently of the server blades and interconnects In the 3U power subsystem, DC circuit breakers enable shutting off the power to individual server...
  • Page 31: Hp Bladesystem P-Class Diagnostic Station

    HP BladeSystem p-Class Diagnostic Station The HP BladeSystem p-Class Diagnostic Station enables a server blade or interconnect switch to be powered up outside of a server blade enclosure for testing or diagnostic purposes. The diagnostic station contains a power supply and connectors for data transfer between the server blade or interconnect switch and a client device (such as a PC, notebook, or workstation).
  • Page 32: Hp Bladesystem P-Class Diagnostic And Local I/O Cables

    HP BladeSystem p-Class diagnostic and local I/O cables HP BladeSystem p-Class systems are optimized for use with HP ProLiant Essentials Rapid Deployment pack (RDP) for software installation and deployment from a centralized deployment console. Local console and I/O connections are available through diagnostic and local I/O cables. •...
  • Page 33: Hp Bladesystem Management Software Overview

    HP BladeSystem Management Software overview HP highly recommends that you become familiar with the tools shown in Table 17, which are used to set up, configure, and manage the HP BladeSystem solution. This table serves as a getting started checklist and as a pointer to more information about these tools. Table 17: Key Management Components Tool Function...
  • Page 34: Hp Bladesystem P-Class Operating System Installation Options

    Table 17: Key Management Components (continued) Tool Function Where to Find HP BladeSystem ProLiant BL Interconnect Switches provide both Ships with HP BladeSystem p-Class Interconnect Switch command line and Web-based interfaces for Interconnect Switch Kits. configuration and configuration and management of interconnect management switches within server blade enclosures.
  • Page 35: Hp Proliant Essentials Rapid Deployment Pack

    HP ProLiant Essentials Rapid Deployment Pack RDP provides a remote console-based method for scalable, automated server deployment without network degradation. RDP can be used to deploy from up to 100 server blades in 30 minutes. In addition, RDP for Windows (version 1.40 or later) includes the added ability to identify and deploy interconnect switches.
  • Page 36: Integrated Lights-Out Advanced Edition

    HP SIM also helps keep blade BIOS, drivers, and agents up to date through system software version control. HP SIM will automatically download the latest firmware components from the HP website and identify systems that require updates, either by comparing target servers to a customer-defined system software baseline or to the latest software published by HP.
  • Page 37: Hp Bladesystem P-Class Interconnect Switch Management

    HP BladeSystem p-Class Interconnect Switch Management The HP BladeSystem p-Class GbE and GbE2 Interconnect Switches are industry-standard managed Ethernet switches that customers configure and manage in the same manner as other industry-standard Ethernet switches. To aid users during initial deployment, the interconnect switch includes a default configuration that is fully operational at initial boot.
  • Page 38: Planning For A Hp Bladesystem P-Class Installation

    Planning for a HP BladeSystem p-Class installation The HP BladeSystem p-Class Sizing Utility is a free, flexible, graphical tool that provides valuable information necessary to help plan and prepare a site for delivery and installation of HP BladeSystem p-Class solutions and order the necessary components for the installation. Site planning information, such as power requirements and environmental specifications, is generated based on user-defined system configuration criteria.
  • Page 39: Required Input Power

    Figure 27. HP BladeSystem Equipment List Output Example Equipment List This Equipment List can be copied to an excel worksheet or word document. To copy this table, select the table using the mouse. Copy the selected table using Copy command from the Edit menu. Go to the destination document and paste it.
  • Page 40: Facility Dc Power Connection

    Figure 28: Maximum output power capacity For more information about the HP BladeSystem p-Class Sizing Utility, refer to http://www.hp.com/go/bladesystem/sizingutility Facility DC power connection Facility DC power requires a Facility DC Power Connection Option Kit to distribute the current through the mini or scalable bus bars to the server blade enclosures. The HP BladeSystem p-Class system requires –48 VDC with no more than ±10% voltage variance.
  • Page 41: Ac Connectors For The 3U Power Enclosure

    Figure 29. 3U power enclosure connectors AC connectors for the 3U power enclosure Table 18 shows the four models of power enclosure connectors that are available. Table 18. Power Enclosure Connectors and Compatibility Item Two Circuits/ Model Typical Electrical Service Compatibility Connectors L6-30...
  • Page 42: Deployment Considerations: Hp Bladesystem P-Class Network Interconnects

    Deployment considerations: HP BladeSystem p-Class network interconnects The RJ-45 Patch Panel, RJ-45 Patch Panel 2, GbE Interconnect Switches, and GbE2 Interconnect Switches may be mixed within the rack, but not within the same server blade enclosure. The corresponding interconnect modules may also be mixed within the rack, but not within the same server blade enclosure.
  • Page 43 The optional GbE2 Storage connectivity kit provides pass-through of ProLiant BL20p G3, ProLiant BL25p, ProLiant BL30p, BL35p, and ProLiant BL45p FC signals. This kit includes two OctalFC interconnect module connect modules, each with eight SFF slots. The SFF transceivers with LC connectors shipped with each BL20p G3, BL25p, or BL45p Dual Port FC Mezzanine Card are installed in the OctalFC SFF slots.
  • Page 44: Deployment Considerations: Proliant Bl P-Class Gbe Interconnect Switches

    Table 20: Ethernet and FC Cable Requirements (continued) Interconnect Ethernet F-GbE2 Interconnect 1 to 8 optical cables with LC connectors per server Requires Storage Connectivity Kit blade enclosure 1 to 4 cables per server blade enclosure 1 cable for the centralized server blade management module on enclosures with enhanced backplane components Storage Connectivity...
  • Page 45: Server Blade Quantity

    Server Blade Quantity For site planning, the assumed quantity of server blades should be the total number of server blades that will be deployed over the life of the installation. Planning for growth is necessary to ensure that you purchase the appropriate power subsystem components (power enclosures and bus bars) and quantities of server blade enclosures.
  • Page 46: Site Recommendations

    Site recommendations The HP BladeSystem p-Class Sizing Utility provides environmental load estimates (total DC and AC power consumption, generated heat in BTU, weight and floor space requirements) based on the configuration. This information can be useful when planning and managing the data center environment.
  • Page 47: Total Floor Space

    Total floor space To enable servicing and adequate airflow, observe the following spatial requirements when deciding where to install an HP, Compaq, telco, or third-party rack: • Leave a minimum clearance of 63.5 cm (25 in) in front of the rack. •...
  • Page 48 © 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.

Table of Contents