Remove the connection block cover on the side of the boiler case and disconnect
5.
the two electrical wires where they join the heater leads in the connection
block.
Remove the grounding screw,
6.
Remove the flue and the flue baffle,
7.
8.
Remove the screws "B" holding the absorption unit onto the back of the
r e f r i g e r a t o r ( f i g . 4 6 ) .
9.
Release the Piezo electrode from burner housing.
Remove the fastening screw on the burner housing and remove the
10.
burner housing from the boiler case,
11.
Carefully slide absorption unit straight out of the cabinet.
CAUTION :
Be careful not to damage the inner liner and the locations of the fastening
strips ("A" fig. 48) on the evaporator should be noted at this time as they
have to be fitted on the new unit,
To replace absorption unit, reverse above procedure.
12.
CAUTION :
Be sure to apply sealing permagum ("B" fig. 48) on the unit mounting plate.
Be sure to fit the fastening brackets (A) on the evaporator coils in the right
p o s i t i o n s , otherwise it will be difficult to refit the 6 fastening screws
inside the freezer.