GS C1 n1 n2 n3 n4 n5 n6
[Function]
[Code]
[Range]
[Outline]
[Default]
[See Also]
[Sample Program]
[Print Result]
Setting the numbering counter mode (A)
<1D>H<43>H<31>H<n1><n2><n3><n4><n5><n6>
0
n1 , n2 , n3 , n4 , n5 , n6
This command sets the numbering(serial number counter)
mode.
n1 + n2 x 256(n1 = remainder, n2 = quotient) : Counter default
n3 + n4 x 256(n3 = remainder, n4 = quotient) : Counter final value
n5
n6
(n1 + n2 x 256) < (n3 + n4 x 256)
(n1 + n2 x 256) > (n3 + n4 x 256)
(n1 + n2 x 256) = (n3 + n4 x 256)or n5 = 0 or n6 = 0 : Counter stop
n1 + n2
256 = 1
n3 + n4
256 = 65535
n5 = 1
n6 = 1
GS C0 , GS C2 , GS c , GS C ;
LPRINT CHR$(&H1D) ;"C0";
LPRINT CHR$(3);CHR$(0);
LPRINT CHR$(&H1D);"C1";
LPRINT CHR$(50) CHR$(0);
LPRINT CHR$(0);CHR$(0);
LPRINT CHR$(5);CHR$(2);
GOUSAB *CNT
LPRINT CHR$(&H1D);"C2"
LPRINT CHR$(5); CHR$(0);
GOUSAB *CNT
END
50 50 45 45 40 40 <
5 0 50 45 40 35 <
— 107 —
255
*CNT
FORI = 1 TO 5
LPRINT CHR$(&H1D)"c";
NEXT I
LPRINT CHR$(&HA);
RETURN
When setting a count-down range = 0 to 50 step
value = 5, repeat count = 2, and start value = 5 to
print a counte value.
When setting a count-down range = 0 to 50, step
cleared)
: Counter step value
: Idential counter print counter
: Count-up system
: Count-down system