Burnham 8H Series Installation And Operation Manual page 63

Gas-fired boiler
Hide thumbs Also See for 8H Series:
Table of Contents

Advertisement

F.
Clean Combustion Chamber by vacuuming. Exercise
care to avoid damaging Base Insulation.
G.
Install Burners by reversing procedures used to
remove burners. Verify Main Burners are properly
located on support bracket in Base Rear Panel, seated
on Main Burner Orifices, and secured with hitch pin
clips. Verify Main Burner with Pilot Bracket is in
proper location. See Table 13.
H.
Lubrication. Manufacturers Instruction should be
followed on all parts installed on boiler requiring
lubrication. This includes type of lubricant to be used,
frequency of lubrication, and points to lubricate.
I.
Check operation. Refer to Section VIII: System Start-
up.
Figure 53: Boiler Flueway Cleaning
Table 3: Pilot Burner Location
Boiler Model
Pilot Located Between Burners*
805H
806H
807H
808H
809H
810H
*
Burners numbered left to right as viewed from front of boiler.
4 & 5
5 & 6
6 & 7
6 & 7
7 & 8
8 & 9
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

805h806h807h808h809h810h