Exhaust Connection - AEG FM 2500DD-A Instruction Book

Downdraught extractor
Table of Contents

Advertisement

Connection
Min. cable size: 0.75 mm² Cable
type: HO5VV-F
Installation must comply with any
special requirements laid down by
the local energy provider. The prod-
uct must be connected via an exter-
nal switch that disconnects all poles
with a contact gap of at least 3 mm.
(May be the main switch).

Exhaust connection

Exhaust connection:
The connecting piece for the hose or
pipe has a diameter of 120 mm.
The exhaust hose must be at least 1
m long.
Make sure that the connection is
completely airtight.
The cooker hood must be
connected to an exhaust
hose or pipe. It is vital that
this connection is made for
reasons of safety, and the
cooker hood must not be
connected to the power sup-
ply before the exhaust
hose/pipe has been connect-
ed. If the outlet is in a wall,
it must be fitted with a grille
or the like.
PE
23
L
L2
L1
N
N

Advertisement

Table of Contents
loading

Table of Contents