Combustion-Air And Vent Piping - Bryant 355MAV Installation, Start-Up, And Operating Instructions Manual

Series f deluxe 4-way multipoise variable-capacity direct-vent condensing gas furnace installation, start-up, and operating instructions
Table of Contents

Advertisement

EAC-ELECTRONIC AIR
CLEANER TERMINALS
(115-VAC 1 AMP MAX)
4. Follow the lighting instructions. Place the appliance being inspected in operation. Adjust thermostat so appliance shall operate continuously.
5. Test for draft hood equipped appliance spillage at the draft hood relief opening after 5 minutes of main burner operation. Use the flame of
a match or candle.
6. After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors,
windows, exhaust fans, fireplace dampers, and any other gas-burning appliance to their previous conditions of use.
7. If improper venting is observed during any of above tests, the venting system must be corrected.
Vent system or vent connectors may need to be resized. For any other appliances when resizing vent systems or vent connectors, system or
connector must be sized to approach minimum size as determined using appropriate table found in the NFGC or NSCNGPIC.
B. Combustion-Air and Vent Piping
GENERAL
Combustion-air and vent pipe, fittings, primers, and solvents must conform to American National Standards Institute (ANSI) standards and
American Society for Testing and Materials (ASTM) standards. See Table 6 for approved materials for use in the U.S.A. See Table 7 for maximum
pipe lengths and Fig. 39, 40, 41, 42, and 43 for exterior piping arrangements.
In Canada, construct all combustion-air and vent pipes for this unit of CSA or ULC certified schedule-40 PVC, PVC-DWV or ABS-DWV pipe
and pipe cement. SDR pipe is NOT approved in Canada.
MAIN BLOWER
CONTROL WIRE
CONNECTOR
TRANSFORMER
24-V CONNECTORS
CONTINUOUS
FAN (CF) SETUP
SWITCHES
COMMUNICATION
CONNECTOR
Fig. 31—Control Center
Fig. 32—EAC Terminals on Control Center
HOT SURFACE
IGNITOR CONNECTOR
115-V
CONNECTORS
PRESSURE SWITCH
CONNECTOR
24-V THERMOSTAT
TERMINALS
DEHUMIDIFY ENABLE (DE)
DEHUMIDIFIER (DEHUM)
CONNECTOR
3-AMP FUSE
STATUS AND DIAGNOSTIC
LED LIGHTS
AIR CONDITIONING
(A/C) SETUP SWITCH
SETUP SWITCHES
(SW) AND BLOWER
OFF DELAY SETUP
SWITCHES
MODEL PLUG
EAC1
EAC2
—29—
HUM-HUMIDIFIER
TERMINAL
(24-VAC 0.5 AMP MAX)
A99097