TYPICAL INSTALLATION — HIGH-WALL SYSTEMS, 9,000 AND 12,000 BTUH
LEGEND
NEC — National Electrical Code
*Standard.
†Field supplied.
NOTES:
1. All piping must follow standard refrigerant techniques.
2. Do not install a filter drier in mixed phase liquid line.
3. All wiring must comply with applicable local and national codes.
4. Capillary tube expansion device (cooling-only systems only) is located in the
outdoor unit. Both refrigerant lines must be insulated.
5. Wiring and piping shown are general points-of-connection guides only and are
not intended to include all details for a specific installation.
6. Insulate condensate line drain if installed in a conditioned space.
(Cooling-Only System Shown)
17